Configuration
Factory settings
Factory settings see
FBO1200 brief overview of all commands
.
Configuration options
co
mm
and
function
manually
configo
TM
as of version
1.8.x
10
enter a PIN
x
x
11
determine the dialing register number for the sensor
x
x
12
enter or delete a call number in the dialing register
x
–
13
check the of the dialing register XX
x
–
14
not available
acknowledgement: invalid entry
–
–
15
set the minimum duration of a conversation
x
x
16
determine the number of calls until the TK-Interface accepts the call
x
x
17
set the activation time of the output port for
button
x
x
18
not available
acknowledgement: invalid entry
–
–
19
service function listen-in
x
–
20
not available
acknowledgement: invalid entry
–
–
21
not available
acknowledgement: invalid entry
–
–
22
train an internal client to the
buttons 4 / 5 / 6,
delete the
buttons 4 / 5 / 6
x
x
23
control the remote maintenance
x
–
24
define the function of the sensor
x
x
25
define the type of the connection start.
Not in case of a call diversion!
x
x
26
set the delay of the dialing start
x
x
27
not available
acknowledgement: invalid entry
–
–
28
not available
acknowledgement: invalid entry
–
–
29
not available
acknowledgement: invalid entry
–
–
30
duration of the call for this dialing register
x
x
31
control of the connection establishment
x
x
32
control of the override tone during a call from a front-door station
x
x
33
enter the AS-address to the sensor in case of a voice connection
x
x
34
starts the transmission of the internal parameter block of the TK-
Interface
–
–
35
starts the read-out of the parameter block to the dialing register
–
–
36
enter the project number with 4 digits
x
–
37
control of the error output tone
x
x
38
set the function of an internal call to the TK-Interface
x
x
39
activate the function input PIN
x
x
40
set the timeout after the dialing
x
x
41
set the door release command
x
x
42
not available
acknowledgement: invalid entry
–
–
43
set the reaction on a call at the TK-Interface
x
x
44
blank dial tones / do not modify
x
x
45
acoustic
note “call at the TK-Interface“ when incoming call on / off
x
x
46
number of dialing register / set the type of the TK-Interface
–
–
47
not available
acknowledgement: invalid entry
–
–
48
not available
acknowledgement: invalid entry
–
–
49
max. permitted loop resistance between TK-Interface and power supply
and control unit
x
x
* in Zusammenhang mit Konfiguration der Außenstation