GB
52
10/2016
TCS TürControlSysteme AG, Geschwister-Scholl-Str. 7, 39307 Genthin, Germany
Subject to change without notice.
Phone.: +49 (0) 3933 8799-10
Fax: +49 (0) 3933 8799-11, www.tcsag.de
PI_PZF5000_Art0017793.doc 4 A
Programming
2a
Access code define or
change
First access code
Second access code
etc.
Entry:
* 0 # SpNr1 # access code # access code #
Entry:
* 0 # SpNr2 # access code # access code #
SpNr = 1 to 10
Max. access code six-digit
Changing the old code by overwriting with the new code.
2b
Activate or deactivate
R-contact for a code
Entry:
* 1 # SpNr # R #
R – R-contact function
SpNr = 1 to 10
(WE = 1 for SpNr 1 to 10)
R =
1
ON
0
OFF (R-contact without function)
2c
Define transmission
protocol at code entry
Entry:
* 2 # SpNr # P #
P – Protocol selection
SpNr = 1 to 10
(WE = 0 for SpNr 1 to 10)
P = 0 (door opener protocol with own AS address)
1 (Control Function 1 with own serial number)
6 (Control Function SpNr with own serial number)
7 (Do not transmit any protocol)