Acoustic and optical ack-
nowledge on receiving of a
short door opener protocol
By option
Accept door opener protocols
(cp.
Programming,
page 52
,
2f
)
Illuminated buttons
Indirect, blue
Change of data records
and parameters
AS-addresse, R-contact switch time and factory settings manually
programmable
EEPROM memory
All programmed data records and parameters are stored in the
EEPROM.
Power supply and control unit
Overload protection for P wire If the maximum load limit (110 mA) is exceeded the integrated
fuse switches the output off. After removal of the overload and
cooling down of the fuse the output will automatically be
switched back on.
Internal light switch relay
For triggering light control units 24 V / 1 A
Internal door release relay
12 V, 50/60 Hz / 2 A
(for door opener not less than 6 ohm)
Door release time
Manually adjustable, from 0.8 sec to 8 sec
Light switch time
Manually adjustable, from 0.8 sec to 5 min
Single voice channel
Communication between front-door and in-house station over
more than one subsystem is not possible.