Initiation of the programming
0
Only if the function 2f, option 4 is pro-
grammmed:
Switch on programming mode of the
system and switch off again
(WE = 0)
On power supply and control unit:
Briefly press RUN/PROG button, LED flashes.
Briefly press RUN/PROG button, LED
comes ON.
On AZF50000:
Two-colored LED flashes green for 2 min
1
Move the device into the programming
mode
Enter master code
(Begin the programming within
2 min
!)
Correct
entry
Incorrect entry, unknown master
code
No entry
Entry: *
Mastercode
#
.
(WE = 123456)
A positive acknowledgement tone (single
beep) sounds for 3 sec, flashes LED green
(2 min).
The device is ready for programming.
A negative acknowledgement tone (triple beep) sounds
on activation of the #-button.
If code is 3x incorrectly: code entry is blocked for 2 min.
Start again from the beginning.
For 2 min no command: programming mode ends.