Example circuit 3: TCS:BUS with BVS20-SG
Fig. 6: example circuit 3
Door opener in mixed installation
If, in addition to the AZC41000, there are also audio and/or video front-door stations installed,
the function “Switch door release relay with door release protocol” must be activated using
configo
TM
(is already activated in the delivery state). The same AS-address must be assigned
to the AZC41000 as to the front-door station of the associated door. It is not necessary to con-
nect an FAA11000 or FAA1200 door release relay to the audio/video front-door station.
Adapting the device
Adapting the device
The transponder reader is factory set for systems with loop resistance of
≤
20 Ohm and operation on the
TCS:BUS (3-wire technique). The adjustment is made at a DIP switch which is secured with a plastic
plate. See device overview, p. 7.
Only remove the self-adhesive plastic plate on the DIP switch if you need to make an adjust-
ment.
Adjust systems without P-wire (2-wire operation)
Requirement: Only one reader can be connected per
power supply and control unit.
For new installations, a P-wire must be provided.
►
Remove the plastic plate.
►
Set switch 1 to ON if there are only two lines in a system.
Switch 1
2-wire technique
3-wire technique
a)
Fig. 7: DIP-switch 1
a) factory preset
door opener
light