TCS AZC41000-0010 Product Information Download Page 1

 

 

 

Product information 

transponder reader  

AZC41000-0010 

 

 

 

 

 

 

Summary of Contents for AZC41000-0010

Page 1: ...Product information transponder reader AZC41000 0010 ...

Page 2: ...2 ...

Page 3: ... Example circuit 1 TCS BUS with VBVS05 10 Example circuit 2 installation with multiple transponder readers 10 Example circuit 3 TCS BUS with BVS20 SG 11 Door opener in mixed installation 11 Adapting the device 11 Adapting the device 11 Activate infrared remote control 12 Initial operation 12 Error detection and indication 12 Settings 12 Configuration 13 Possible configurations 13 Initial commissio...

Page 4: ... notices Symbol signal word Explanation DANGER The signal word describes an endangering with a high level of risk Failure to observe this warning will result in death or very serious injury WARNING The signal word describes an endangering with a medium level of risk Failure to ob serve this warning could result in death or very serious injury CAUTION The signal word describes an endangering with a...

Page 5: ...ss sections can be used in compli ance with the loop resistance Requirements to protect against lightning CAUTION Device damage due to over voltage By suitable lightning protection measures it has to be ensured that the electric voltage of 32 V DC at each connection is not to be exceeded Product description Intended use The transponder reader is a transponder unit to read transponder keys and card...

Page 6: ...free relay contact two way switch 24 V DC 2 A Adjustable door opening time factory settings at 3 seconds Sabotage contact Update possible via ISP interface The device is based on another technology such as the transponder readers tLeser GH and tPAKL EN Transponder of types tKey01 and tCard01 cannot be used Display and control elements LED green On 3 s transponder card recognized access granted Bli...

Page 7: ...e partially visible 1 attachment hole 1 2 7 flush panel 2 cable gland 8 LED green red orange 3 DIP switch 9 opening for win clipTM key 4 sabotage contact 10 nameplate glass 5 attachment hole 3 11 IR receiver 6 print card 12 connection terminal ...

Page 8: ... range at least 1 m in open spaces 15 deviation from direction at a distance of 3 m operating temperature 10 to 50 C storage temperature 20 to 60 C remote control batteries button cell battery CR2025 DC3 0 V Mounting and installation win clipTM System The device is equipment with the win clipTM system to open and close the station without using any screws Open the housing Push the enclosed win cli...

Page 9: ...oam cover on the backside of the device ATTENTION Damage to the connection wires Ensure that the cables from the rear panel do not get clamped Mount the device via the mounting holes onto the wall using suitable screws Connecting the lines Connecting lines Allowed cross section diameter 0 08 1 mm2 Ø 0 3 1 4 mm Max number of wires per terminal contact 2 x 0 8 mm or 3 x 0 6 mm Connect further wires ...

Page 10: ...TCS BUS with VBVS05 Fig 4 example circuit 1 Example circuit 2 installation with multiple transponder readers Fig 5 example circuit door opener with separate power supply door opener door opener door opener door opener light ...

Page 11: ...ront door station Adapting the device Adapting the device The transponder reader is factory set for systems with loop resistance of 20 Ohm and operation on the TCS BUS 3 wire technique The adjustment is made at a DIP switch which is secured with a plastic plate See device overview p 7 Only remove the self adhesive plastic plate on the DIP switch if you need to make an adjust ment Adjust systems wi...

Page 12: ...cuit de vice goes into stand by mode again a wire not connected or not supplied connect a wire or check power supply device goes into stand by mode again Sabotage contact activated control function 199 with own serial number for silent alarm is sent insert nameplate correctly Settings Sabotage contact When the sabotage contact is activated a protocol is sent and an error message is displayed LED f...

Page 13: ...vice Master transponder code 00000000 no master transponder TCS BUS connected YES Sabotage contact activated ON 1 control function in case of sabotage 199 Configuration Possible configurations Function Infrared remote control Master transponder configoTM train transponder x limited to 50 x limited to 10 x limited to 250 delete transponder x delete individually number memory address must be known x...

Page 14: ...n ON for 3 s Transponder card recognized access granted flashes ready for programming in programming mode via infrared remote control or master transponder red ON for 3 s Transponder card not recognized ON for 2 min lock wait after triple entry of an incorrect master code via infrared remote control triple use of an incorrect master transponder triple use of an incorrect transponder flashes delete...

Page 15: ...e command sequence is also rejected and a negative acknowledgement tone sounds When operating the infrared remote control always aim the head of the remote control directly at the front door station The range of the infrared remote control is max 1 m in direct distance Each press of a button on the infrared remote control is confirmed by the transponder reader with a short acknowledgement tone For...

Page 16: ...is confirmed by the device with a short button acknowledgement tone master code WE 6 digit serial num ber of the transponder reader WE factory setting a positive acknowledgement tone sounds LED lights green for 3 s LED blinks green A negative acknowledgement tone sounds when pressing the key LED lights red for 3 s LED lights green again The code entry is blocked for 2 min after the code has been e...

Page 17: ... SpNr SpNr memory location 0 to 49 Hold the transponder in front the de vice a positive acknowledgement tone sounds LED lights green for 3 s LED blinks green again Repeat the steps below LED blinks orange LED lights orange A negative acknowledgement tone sounds when the transponder is held in front of the device LED lights red for 3 s LED lights green again Delete the occupied memory address Or de...

Page 18: ...ds LED lights green for 3 s LED blinks green again a negative acknowledgement tone sounds LED lights red for 3 s LED blinks green again Delete all transponders Initiate program ming If not yet done Enter command All transponders are deleted 94 Mastercode Mastercode Mastercode 6 digit number a positive acknowledgement tone sounds LED lights green for 3 s LED blinks green again Number of transponder...

Page 19: ...acknowledgement tone sounds LED lights green for 3 s LED blinks green again a negative acknowledgement tone sounds LED lights red for 3 s LED blinks green again Set AS address Initiate program ming If not yet done Enter command AS address is set incorrect value has been entered 4 Wert AS address 0 bis 63 WE 0 a positive acknowledgement tone sounds LED lights green for 3 s LED blinks green again a ...

Page 20: ... 8 s until presenting the transponder Shortly hold any transponder in front of the nameplate glass a positive acknowledgement tone sounds LED lights green for 3 s LED blinks green again a negative acknowledgement tone sounds LED lights red for 3 s LED blinks green again When training another transponder as master transponder the previously trained one will be overwritten We recommend marking the m...

Page 21: ...ks green again The code entry is blocked for 2 min after the wrong master codes has been entered wrong 3 times Change master code For safety reasons the master code set ex works should be changed when commissioning Initiate program ming If not yet done Enter command master code is changed wrong entry unknown master code 98 old master code new master code new master code Mastercode 6 digit number a...

Page 22: ...Enter command or wait end 9 LED OFF no programming for 2 min a positive acknowledgement tone sounds LED lights green for 3 s LED is OFF again The front door station is still ready for programming for the next 5 min The programming must not be initiated again ...

Page 23: ...mming authorization via master transponder present master tran sponder Master transponder is recognized device ready for pro gramming wrong unknown master transponder No input Hold the master transponder in front of the nameplate glass a positive acknowledgement tone sounds LED lights green for 3 s LED blinks green again a negative acknowledgement tone sounds LED lights red for 3 s LED goes OFF Th...

Page 24: ...r memory ad dress The transponder number is written in the next available memory address SpNr memory address 00 bis 09 Shortly hold the transponder in front of the nameplate glass a positive acknowledgement tone sounds LED lights green for 3 s LED blinks green again Repeat the steps LED blinks orange LED lights orange a negative acknowledgement tone sounds LED lights red for 3 s LED blinks green a...

Page 25: ...e acknowledgement tone sounds LED flashes green briefly LED blinks red for 8 s As long as the LED blinks red shortly place the master transponder in front of the nameplate glass again a positive acknowledgement tone sounds LED blinks green again The device goes into programming mode End programming Present master tran sponder or wait Programming mode is ended Shortly hold the master transponder in...

Page 26: ...very with a waterproof pen Take out the name plate glass see win clipTM System p 8 Push the info sign from below into the pockets in the name plate glass Fig 9 Label info sign Operation Hold the electronic key in front of the device with a distance of max 30 mm The LED lights green A simple positive acknowledgement tone sounds when the key is recognized in factory setting The door release contact ...

Page 27: ...ring the device Clean the device with a dry or slightly wet cloth CAUTION Damages on the surface of the device Abrasive or scratching detergents damage the surface of the device Do not use any abrasive detergents Remove stronger stains with a pH neutral household cleaner Conformity Declarations of conformity are available for download under www tcsag de Information on disposal Dispose the device s...

Page 28: ...ansponder card MCARD01 Transponder key MKEY01 User program access control PCitACC laser fil foil A4 matt 5 pieces SPNA4 Service Please send your questions and inquiries to TCS HOTLINE 04194 9881 188 Headquarters TCS TürControlSysteme AG Geschwister Scholl Str 7 39307 Genthin Germany FON Fax 49 0 3933 8799 10 49 0 3933 8799 11 www tcsag de Subject to technical changes TCS Hotline Deutschland Tel 04...

Reviews: