Connect the lines
!
All modules are permitted exclusivley for safety extra low voltage (SELV) and protec-
tive extra low voltage (PELV).
Commissioning
First install the system completely, than connect it to voltage!
Check the a-, b- and P-wire against each other for short-circuits.
Switch on the power supply.
Note on the connection of more than one front-door station
In a system with a voltage supply realized by a single DC power supply NGV1011-0400,
max. 5 front-door stations with display modules can be connected.
If a front-door stations with modules is operated parallel to other front-door stations with
modules, their AS-addresses must be fix.
The setting can only be realised with the Service Device TCSK-01 or the configuration
software configo
TM
.
Setting the AS-address of a front-door station when using a display module is realised
with a PS/2 keypad via the menu navigation, with the Service Device TCSK-01 or the
software ADx-configurator.