TCP Smart SMAWHHEAT2000WHOR705 User Instructions Download Page 2

3) 

 

Warning: Before using the heater, make sure 

it’s mounted tightly on the wall. 

 

 

LOCATION OF INSTALLATION

 

This product can be installed in a bathroom but only in the area designated by the IP rating 

– Zone 3 – 

see location information below. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

SAFETY INSTRUCTIONS 

(to be read before operating the heater).

 

Before using set the power-level switch which is located at the back of the heater to 
“ ”. Please note: there may be a trace of odour during the first few minutes of initial 
use, or after a period of storage. This is normal and will quickly disappear.

 

 

CAUTION: 

Some parts of this product can become very hot and cause burns. Particular 

attention has to be given where children and vulnerable people are present. Children 3

 

years and younger should be continually supervised when in close proximity to the heater. 
Children aged from 3 to 8 years shall only switch on/off the appliance provided that it has 
been placed or installed in its intended normal operating position and they have been given 
supervision or instruction concerning use of the appliance in a safe way and understand the 
hazards involved.  Children aged from 3 to 8 year shall not plug in, regulate and clean the 
appliance or perform user maintenance.

 

Keep the power cord away from the hot body of the heater. 

Indoor use only.

 

Do not use the heater in areas where flammable liquids are stored or where 
flammablefumes may be present.

 

Do not use this heater if it has been dropped;

 

Do not use if there are visible signs of damage to the heater;

 

Do not leave the heater switched on when your property is vacant.

 

Suitable for indoor only.  This product is rated as IP24.  If the product is to be installed within a bathroom 
it can only be located within zone 3.

 

Zone 0

 

The area inside a bath or inside the shower 

This  area requires low voltage and an IP67 

rating.

 

Zone 1

 

The area above the bath to a height of basin.

 

2.25m (7’ 4””) from the floor. If the light is 

240V then a 30ma residual current device 

(RCD) must also be used to protect the circuit 

in this zone.

 

Zone 2

 

Zone 3

 

An area stretching 0.6m (1’ 11””) outside the perimeter 
of the bath and to a height of 2.25m (7’ 4””) from the 
floor. In addition, it is good practice to consider the area 
around a wash basin, within a 60cm (1’ 11””) radius of 
any tap to be considered as zone 2

 

Anywhere outside Zones 0, 1, and 2 and where no 
water jet is likely to be used. If there is a likelihood of 
water jets being used for cleaning purposes in zones 1, 
2 and 3 a fitting rated a minimum of IP65 must be 
used.

 

Summary of Contents for Smart SMAWHHEAT2000WHOR705

Page 1: ...Provided with a handy remote control especially if installed at a high level Save money through efficiently heating the room and not the home This product is only suitable for well insulated spaces or...

Page 2: ...lug in regulate and clean the appliance or perform user maintenance Keep the power cord away from the hot body of the heater Indoor use only Do not use the heater in areas where flammable liquids are...

Page 3: ...ath a shower or a swimmingpool In order to avoid a hazard due to inadvertent resetting of the thermal cut out this appliance must not be supplied through an external switching device such as a timer o...

Page 4: ...s is pre set as 4 o C below comfort mode Anti frost mode To avoid damage to the product during extreme cold weather use anti frost mode The heater must be turned on and Anti Frost mode selected for th...

Page 5: ...CO mode 08 00am 11 00am comfort mode 11 00am 13 00pm ECO mode 13 00pm 16 00pm comfort mode 16 00pm 20 00pm ECO mode 20 00pm 00 00am comfort mode Monday Friday Programmable schedule Please note that th...

Page 6: ...day setting When screen displays press to set scheduling And BUTTONS Use these buttons to increase or decrease the temperature and to increase or decrease time within timer function This feature can b...

Page 7: ...ibility of an open window in the room If this happens it will stop heating and enter standby mode To turn on open window function press Mode and buttons together and the screen will display after 3 se...

Page 8: ...Consumer Products Ltd declares that the radio equipment type TCP Smart Wifi Fan 1500W White TCP Smart Wifi Fan 1500W Black is in accordance with Directive 2014 53 EU The full text of the EU declarati...

Page 9: ...s running on 2 4Ghz and not 5Ghz If you are unsure please consult your broadband provider for details on how to change the settings Turn off any Wi Fi extenders during set up Check you do not have any...

Page 10: ...Anti Frost Mode Open Window function Mode P3 Timer Mode On Off Temperature Setting Use and buttons to set target temperature Countdown Timer Use the and button to set a countdown from 1 to 9 hours Fr...

Page 11: ...programme can then be activated by pressing the corresponding P1 P2 or P3 symbol Press to turn off Anti Frost For this function to work the heater must be turned on Once the Anti frost mode is selecte...

Page 12: ...nominal heat output elmax 0 kW Type of heat output room temperature control select one At minimum heat output elmin 0 kW single stage heat output no room temperature control No In standby mode elSB 0...

Reviews: