39
WIFI CONTROL TROUBLESHOOTING
Description
Possible Cause
Air conditioner
can’t be configured
successfully
1. Check the mobile device is connected to WIFI
2. Check the AC is connected
3. Check that any firewall or other restrictions are causing problems
4. Check the router is functioning normally
5.
Check that the router isn’t blocking the App
Mobile device can’t
control the air
conditioner
The app displays “Identification failed”. This indicates that the AC has
been reset and the mobile device has lost contact with the AC.
Reconnect the device following the above instructions. If this fails, delete
the AC from your devices list and start the install process from the
beginning.
Mobile device can’t
find AC
The app displays “Air conditioner out of line”. Check the below:
1. The AC has been reconfigured
2. The AC is not receiving power
3. The router is not powered on
4.
The AC can’t connect to router
5.
The AC can’t connect to network through the router
6.
The mobile device can’t connect to the router
7.
The mobile device can’t connect to a network (when being used
remotely)
TECHNICAL SPECIFICATION
Model
Iqool9
– v3
Iqool12
– v3
Iqool18
– v3
Iqool24
– v3
Rated voltage and frequency
(Ph-V-Hz)
1Ph/220-
240V~/50Hz
1Ph/220-
240V~/50Hz
1Ph/220-
240V~/50Hz
1Ph/220-
240V~/50Hz
Fuse Required
13A
13A
13A
16A
Mode
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Rated capacity (W)
2520
(900
~
3200)
2570
(900
~
3200)
3230
(1000
~
3720)
3290
(1000
~
3830)
5120
(1310~
5730)
5230
(1330~
6540)
6810
(1500~
7310)
6850
(1500~
7530)
Power input (W)
740
(300
~
1265)
640
(230
~
1200)
1090
(320
~
1300)
1000
(320
~
1450)
1500
(500
~
2100)
1500
(500
~
2350)
1940
(350~
2800)
1988
(300~
3200)
Current input (A)
4.3(1.3~
5.5)
3.2(1.3~
6.4)
5.2(1.4
~
6.5)
4.6(1.4
~
5.9)
6.7(2.3~
9.6)
6.7(2.3~
10.8)
8.5(1.7~
13.5)
8.7(1.5
~15.5)
SEER/SCOP(W/W)
6.1/A++
4.0/A+
6.1/A++
4.0/A+
6.3/A++
4.0/A+
6.3/A++
4.0/A+
Nominal load (kW)
2.52
2.57
3.23
3.29
5.12
5.23
6.81
6.85
Balance point temperature
heating (
o
C)
/
-7
/
-7
/
-7
/
-7
Min. outdoor operating
temperature (
o
C)
/
-15
/
-15
/
-15
/
-15
Thermostat-off mode (W)
35
35
51
42.5
Standby mode (W)
4
4
2
6.76
Off mode (W)
0
0
0
0
Summary of Contents for iQool9
Page 24: ...24 RECOMMENDED INSTALLATION SPACING DIAGRAM ...
Page 28: ...28 65 65 ...
Page 33: ...33 ELECTRICAL WIRING DIAGRAMS INDOOR UNIT Iqool9 12 18 Iqool24 ...
Page 34: ...34 OUTDOOR UNIT Iqool9 12 Iqool18 ...
Page 35: ...35 Iqool24 ...