TCL Air Conditioner Service Manual
18
Room Temp.
Set TEMP.
+
1
℃
Set TEMP.
-
1
℃
Time
More than 2 min
More than 2 min
More than 2 min
More than 2 min
More than 2 min
Indoor Fan
Set Speed
Set Speed
Set Speed
Set Speed
Set Speed
Compressor
ON OFF ON OFF ON
Outdoor
Fan ON OFF ON OFF ON
4. “DRY” Mode Operation
(1) The system for DRY operation used the same refrigerant circle as the cooling circle.
(2) When the system operates in DRY mode ,at first it operates in cooling mode at 18
℃
for 3 minutes, and
then, the system operates in cooling mode with low speed that regards the temperature of the room
temperature sensor reads decrease 2
℃
as the set temperature. During the course of this, the fan speed
setted operation is failing but the vane motor can be controlled.
5. “HEATING” Mode Operation (Only available for Heat Pump)
(1) When the HEATING mode is selected without setting temperature, the system will set the temperature at 23
℃
automatically with the AUTO FAN speed.
(2) When selecting the HEATING mode operation, the system will operate according to the setting by the
remote controller and the operation is as following:
Set Temp.
+
1
℃
Set Temp.
-
1
℃
Room Temp.
Time
More than 2 min
More than 2 min
More than 2 min
More than 2 min
More than 2 min
Compressor
ON
OFF
ON
OFF
ON
Outdoor fan
ON
OFF
ON
OFF
ON
(3) In HEATING mode, the indoor fan motor is controlled by Cold Air Prevention Control.
(4) Cold Air Prevention Control
The function is intend to prevent cold air from being discharged when the heating operation starts or
when defrosting.
The indoor fan speed will be controlled as following:
The vane angle is at the angle C(100
°
).
34
℃
30
℃
27
℃
25
℃
23
℃
OFF UL Set Speed UL OFF UL
Indoor Pipe
T
emperature