TCi MSD0480A000 Installation, Operation And Maintenance Manual Download Page 14

MSD Manual 

2.0 General Information

 

 

10

 

 

Table 1– MSD 480 Volt Models in UL Type 1/3R Enclosures 

Model 

Number 

Horsepower 

Current 

Rating (Amps) 

Weight  Height 

(in.) 

Width 

(in.) 

Depth 

(in.) 

Watts 

Loss 

MSD0009A300 

57 lbs  

(25.9 Kg) 

19.13 in  

(49 cm) 

15.50 in  

(39 cm) 

19.50 in  

(50 cm) 

102 

MSD0012A300 

7.5 

12 

58 lbs  

(26.3 Kg) 

19.13 in  

(49 cm) 

15.50 in  

(39 cm) 

19.50 in  

(50 cm) 

116 

MSD0016A300 

10 

16 

58 lbs  

(26.3 Kg) 

19.13 in  

(49 cm) 

15.50 in  

(39 cm) 

19.50 in  

(50 cm) 

145 

MSD0023A300 

15 

23 

75 lbs  

(34.0 Kg) 

19.13 in  

(49 cm) 

15.50 in  

(39 cm) 

19.50 in  

(50 cm) 

210 

MSD0030A300 

20 

30 

75 lbs  

(34.0 Kg) 

19.13 in  

(49 cm) 

15.50 in  

(39 cm) 

19.50 in  

(50 cm) 

244 

MSD0035A300 

25 

35 

75 lbs  

(34.0 Kg) 

19.13 in  

(49 cm) 

15.50 in  

(39 cm) 

19.50 in  

(50 cm) 

303 

MSD0045A300 

30 

45 

90 lbs  

(40.8 Kg) 

19.13 in  

(49 cm) 

15.50 in  

(39 cm) 

19.50 in  

(50 cm) 

304 

MSD0055A300 

40 

55 

105 lbs 

(47.6 Kg) 

19.13 in  

(49 cm) 

15.50 in  

(39 cm) 

19.50 in  

(50 cm) 

350 

MSD0065A300 

50 

65 

144 lbs  

(65 Kg) 

22.13 in  

(56 cm) 

20.43 in  

(52 cm) 

28.50 in  

(72 cm) 

374 

MSD0080A300 

60 

80 

162 lbs  

(73 Kg) 

22.13 in  

(56 cm) 

20.43 in  

(52 cm) 

28.50 in  

(72 cm) 

546 

MSD0110A300 

75 

110 

177 lbs  

(80 Kg) 

22.13 in  

(56 cm) 

20.43 in  

(52 cm) 

28.50 in  

(72 cm) 

645 

MSD0130A300 

100 

130 

187 lbs  

(85 Kg) 

22.13 in  

(56 cm) 

20.43 in  

(52 cm) 

28.50 in  

(72 cm) 

827 

MSD0160A300 

125 

160 

340 lbs 

(154 Kg) 

36.00 in  

(91 cm) 

28.40 in  

(72 cm) 

36.86 in  

(94 cm) 

683 

MSD0200A300 

150 

200 

425 lbs 

(193 Kg) 

36.00 in  

(91 cm) 

28.40 in  

(72 cm) 

36.86 in  

(94 cm) 

1025 

MSD0250A300 

200 

250 

450 lbs 

(204 Kg) 

36.00 in  

(91 cm) 

28.40 in  

(72 cm) 

36.86 in  

(94 cm) 

1153 

MSD0305A300 

250 

305 

460 lbs 

(209 Kg) 

36.00 in  

(91 cm) 

28.40 in  

(72 cm) 

36.86 in  

(94 cm) 

1290 

MSD0362A300 

300 

362 

470 lbs 

(213 Kg) 

36.00 in  

(91 cm) 

28.40 in  

(72 cm) 

36.86 in  

(94 cm) 

1415 

MSD0420A300 

350 

420 

575 lbs 

(261 Kg) 

36.00 in  

(91 cm) 

28.40 in  

(72 cm) 

36.86 in  

(94 cm) 

1210 

MSD0480A300 

400 

480 

630 lbs 

(286 Kg) 

36.00 in  

(91 cm) 

28.40 in  

(72 cm) 

36.86 in  

(94 cm) 

1460 

MSN0540A300 

450 

540 

700 lbs 

(318 Kg) 

63.95 in 

(163 cm) 

24.58 in 

(62 cm) 

44.00 in 

(112 cm) 

1610 

MSN0600A300 

500 

600 

713 lbs 

(323 Kg) 

63.95 in 

(163 cm) 

24.58 in 

(62 cm) 

44.00 in 

(112 cm) 

1715 

MSN0750A300 

600 

750 

805 lbs 

(365 Kg) 

63.95 in 

(163 cm) 

24.58 in 

(62 cm) 

44.00 in 

(112 cm) 

1805 

MSN0850A300 

700 

850 

850 lbs 

(386 Kg) 

63.95 in 

(163 cm) 

24.58 in 

(62 cm) 

44.00 in 

(112 cm) 

2065 

MSN0960A300 

800 

960 

875 lbs 

(340 Kg) 

63.95 in 

(163 cm) 

24.58 in 

(62 cm) 

44.00 in 

(112 cm) 

2195 

MSN1080A300 

900 

1080 

980 lbs 

(445 Kg) 

63.95 in 

(163 cm) 

24.58 in 

(62 cm) 

44.00 in 

(112 cm) 

2570 

MSN0600A300 

500 

600 

 

64.00 

24.17 

45.00 

2500 

MSN0750A300 

600 

750 

 

 

 

 

 

Summary of Contents for MSD0480A000

Page 1: ...llation Operation and Maintenance Manual TCI LLC W132 N10611 Grant Drive Germantown WI 53022 Phone 414 357 4480 Fax 414 357 4484 Helpline 800 TCI 8282 www transcoil com 2019 TCI LLC All right reserved...

Page 2: ......

Page 3: ...on 12 Variable Frequency Drive Settings 12 Environment 12 Working Space 12 Power Wiring 12 Thermal Switch 13 Optional Features 13 4 0 Installation Guidelines 14 Wiring 14 Before Connecting 14 Over Tem...

Page 4: ...on 6 6 16 17 E Updates to Product Ratings and Dimensions Table Updates to Installation Checklist 9 18 17 F Revision of technical specifications and overall reformat 1015 19 G Updates to Tech Specs 01...

Page 5: ...ion readers about conditions which can if proper steps are not taken lead to a serious fault condition physical injury or death Cautions are used to draw attention to instructions Failure to properly...

Page 6: ...Verify with a voltmeter to make sure that all sources of power have been disconnected and that all capacitors have discharged before beginning work Caution The drive output terminals MotorShield and t...

Page 7: ...checklist for a successful installation These points are explained in detail in the subsequent sections of this manual Receiving Inspection The MotorShield has been thoroughly inspected functionally t...

Page 8: ...is expressly limited at TCI s option to i repair or replacement of that product or ii return of the product and refund of the purchase price Such remedy shall be Buyer s sole and exclusive remedy TCI...

Page 9: ...the output voltage waveform resulting in a nearly pure sine wave voltage profile The MotorShield sine wave filter reduces the effects of the reflected wave phenomenon dV dt which can cause motor heati...

Page 10: ...n Typical Configuration for MSD 480 V 9A to 16A Typical Configuration for MSD 480 V 23A to 45A Figure 1 Typical Configurations for the MotorShield Filter These drawings are for general reference only...

Page 11: ...l Configuration for MSD 480 V 55A Typical Configuration for MSD 480 V 65A and up Figure 2 Typical Configurations for the MotorShield Filter These drawings are for general reference only Use the drawin...

Page 12: ...ge FLA the rated continuous operating current RMS amps System Voltage the maximum VFD output voltage fundamental Hz the maximum VFD output frequency fundamental Phase 3 The MotorShield is designed for...

Page 13: ...ted 110 Amps 480 V Figure 4 MotorShield Model Number Encoding The MotorShield has a current rating rather than a horsepower rating The rating and dimension tables in the following section list the nom...

Page 14: ...72 cm 645 MSD0130A300 100 130 187 lbs 85 Kg 22 13 in 56 cm 20 43 in 52 cm 28 50 in 72 cm 827 MSD0160A300 125 160 340 lbs 154 Kg 36 00 in 91 cm 28 40 in 72 cm 36 86 in 94 cm 683 MSD0200A300 150 200 425...

Page 15: ...ormance Maximum peak voltage of output waveform 480 V models 815 V 600 V models 1 018 V Maximum dV dt of output waveform 480 V models 5 V s 600 V models 6 V s Environmental Conditions Maximum Elevatio...

Page 16: ...oved for such use this equipment is not suitable for use in an explosive atmosphere or in a Hazardous Classified Location as defined in article 500 of the National Electrical Code NEC Make sure that t...

Page 17: ...tors overheat Connect these switches to monitoring equipment Figure 5 Thermal Switches Optional Features Additional wiring requirements may apply to MotorShield units that are equipped with optional f...

Page 18: ...Failure to follow the safety instructions set forth in this manual can result in serious injury or death Warning Exercise caution when connecting the filter to the drive Internal filter components ma...

Page 19: ...35 lb in 4 0 N m B 30 10 AWG 30 lb in 3 4 N m A 30 10 AWG 40 lb in 4 5 N m B 35 8 AWG 30 lb in 3 4 N m A 35 8 AWG 40 lb in 4 5 N m B 45 8 AWG 30 lb in 3 4 N m A 45 8 AWG 45 lb in 5 1 N m B 55 6 AWG 35...

Page 20: ...the requirements of the National Electrical Code NEC and or any other codes that apply to the installation site The ground connection must be made using a wire conductor Metallic conduit is not a suit...

Page 21: ...onfiguration Caution Ensure drive output frequency is set between 2 kHz and 16 kHz Failure to do so may result in damage to the filter Caution Thoroughly check the installation before applying power a...

Page 22: ...icians should carry out all electrical installation and maintenance work on the MotorShield Disconnect all sources of power to the VFD and MotorShield before working on the equipment Do not attempt an...

Page 23: ...ceeds its ratings a switching frequency lower than its minimum specification a motor frequency that exceeds maximum specifications or blocked air flow Check to make sure current drive switching freque...

Page 24: ...ts are needed please contact your TCI representative To ensure that the MotorShield continues to perform to its original specifications replacement parts should conform to TCI specifications Factory C...

Page 25: ...LLC W132 N10611 Grant Drive Germantown WI 53022 Phone 414 357 4480 Fax 414 357 4484 Helpline 800 TCI 8282 www transcoil com 2019 TCI LLC All right reserved Product No 29343 Effective 01 17 20 Version...

Reviews: