TCE Group S.r.l.
Installation, use and maintenance manual
–
Serie KRONOS
23
Purple still
Desolfatazione
Flashing Red
Anomaly (check display for error code)
Troubleshooting
Given the complexity of the machine, it is advisable in case of problems, to contact an authorized dealer or directly
TCE Group Srl.
Below is a data sheet of the main error codes that may occur.
Display
Description
Cause
T sens 1
Primary temperature probe anomaly
Possible breaking of the probe / Disconnection of
the FLAT cable of the control card
T sens 2
Secondary temperature probe anomaly
Possible breaking of the probe
Tfr Sens
Transformer temperature probe anomaly
Possible breaking of the probe
Time out
Timeout during the Bulk phase (0-80%)
Battery could be damaged or wrong voltage
Warning Memory
Error during writing/reading of the
memory in the microprocessor
Anomaly in the microprocessor