In Term Comp
With additional hardware modification, DBMax can be used in
600 ohm terminated environments. Software auto-detects if
hardware modification has been carried out. If hardware has not
been modified, "---" is shown on screen at line "In Term Comp".
If hardware has been modified and "on" is selected, "dBm"
replaces "dBu" for on-screen level measure.
For information on how to achieve this modification please
contact your local TC distributor or authorized TC Electronic
Service center.
Note: New DBMaxes dispatched from TC are not hardware
modified unless requested.
Pedal Input
Function
Select between: External Fader/Fade up-down/Bypass/Preset.
Analog Adjust
In Fine L
Fine adjust for the Left channel Input. This parameter may be
trimmed in 0.1dB steps.
In Fine R
Fine adjust for the Right channel Input. This parameter may be
trimmed in 0.1dB steps.
Out Fine L
Fine adjust for the Left channel Output. This parameter may be
trimmed in 0.1dB steps.
Out Fine R
Fine adjust for the Right channel Output. This parameter may be
trimmed in 0.1dB steps.
Your PIN-code
Set your PIN-code for the security lock by dialing the ADJUST
wheel (See page 36).
If you should forget your PIN-code, please enter the Reset page.
This will release the DBMAX from the locked state.
(You do not have to run any of the reset functions)
A keyboard lock facility is also provided. Press and hold the Help
key for about 3 seconds, and all keys will be locked
including the ADJUST wheel. The display will say
locked
in the
top line. To unlock the keyboard, press Help again for about 3
seconds.
Memory Backup
RAM to Card
Insert a PC Card in the card slot and press OK.
A backup of all RAM presets and User Ref. Levels setups will
now be stored to the memory card.
RAM protect
If you accidently select Card to RAM, when your intention was
to select RAM to Card, the entire RAM will be overwritten.
To avoid this unpleasant scenario you can use the RAM protect
function. If this function is enabled you will not be allowed to
overwrite the RAM bank.
Card to RAM
Insert the PC Card containing your presets and press OK.
All RAM presets and User Ref. Levels setups stored on the
card will now be transmitted to the DBMAX
Warning:
This action will destroy all existing RAM presets of the DBMAX.
RAM to MIDI
Connect your DBMAX’s MIDI Output to another DBMAX, a
sequencer or any other MIDI recording device. Press OK and the
DBMAX will perform a MIDI bulk dump of all RAM presets.
MIDI to RAM
Connect the storing device to the DBMAX’s MIDI Input and
press OK. The DBMAX is now ready to receive a MIDI bulk
dump containing RAM presets.
45
UTILITY