TC Communications TC3301 User Manual Download Page 6

-6-

TC3301 User's Manual

Rev. 1.4

9.  Installation

A.

Connect the standard 12VDC power supply to the TC3301 (24VDC, 48 VDC, 125VDC or 115/230VAC
with an external power cube are optional).

B.

The "PWRA," and/or "PWRB," "1000M,"  "Vcc," LEDs should be lit.

C

.  Use CAT 5E or 6 UTP cable to connect the TC3301 RJ-45 port to the 1000Base-T Port of your network

device. The "FDX," and "LNK," LEDs will be lit. If the LEDs are "Off," please verify the cable
connection and the power of the network device.

D.

Connect the optic cables  according to the example diagrams shown on page 7. For example, on diagram
C; the local TC3301's optic "Tx" should be connected to the remote network device's optic "Rx" and vice-
versa.

E.

After step "D," the "FO" LED should light to indicate that the optical idle signal is being received.

F.

Create some activity on the Ethernet, the "ACT" LED should be lit.

Note: As the Ethernet activity going through the RJ-45 port becomes greater, this LED will become brighter.

G.

Double-check all LEDs according to the following:

The "PWRA," and/or "PWRB," "Vcc," "FO," "1000M,"  "FDX," "LNK," and "ACT" LEDs should be lit.

The "FO" LED will be lit when the optic side has activity and/or fiber optic cables are connected.

The "ACT" LED will be lit when the UTP side has activity.

Summary of Contents for TC3301

Page 1: ...e g network bridges switches or workstation cards to single mode 1300 1550nm or multimode 850nm fiber optics Completely transparent to the network the TC3301R S is ideal for integrating UTP and fiber...

Page 2: ...r 6 0 dBm 1310nm Receiver PIN Diode typical Sensitivity 16 0 dBm 1310nm Optic saturation level 0 dBm 1310nm Loss Budget Multimode 50 or 62 5 125 m 1310nm 10 dB Distance Multimode 50 or 62 5 125 m 1310...

Page 3: ...1550nm Loss Budget Single Mode 9 125 m 1550nm 32dB Distance Single Mode 9 125 m 1550nm up to 120km distance Wavelength Single Mode 1550nm LASER Connector ST FC SC Single One Fiber 40km Model Transmitt...

Page 4: ...ults could be erroneous and confusing 6 Calculating the Loss on the Fiber The fiber optic link and or connectors are frequently the source of various problems Check out the connectors and the integrit...

Page 5: ...dicates the correct operating voltage is being derived from the power source Full Duplex LED indicator Solidly lit when Ethernet signal is in 1000M full duplex mode Link LED indicator Solidly lit when...

Page 6: ...he example diagrams shown on page 7 For example on diagram C the local TC3301 s optic Tx should be connected to the remote network device s optic Rx and vice versa E After step D the FO LED should lig...

Page 7: ...m switch is not closed it indicates an internal problem with the unit For assistance please contact the Technical Support Department at TC Communications 949 852 1973 Electrical Problem If the LNK or...

Page 8: ...onnect the local TC3301 s Tx to the remote TC3301 s Rx and vice versa C Copper to Fiber Connect the optical cables according to the diagram below the local TC3301 s optic Tx should be connected to the...

Page 9: ...n may first inspect such goods at the premises of the Buyer or may give written authorization to Buyer to return the goods to TC Communications Inc transportation charges prepaid for examination by TC...