TC Communications TC3301 User Manual Download Page 4

-4-

TC3301 User's Manual

Rev. 1.4

These are the reference values we use to calculate the loss on the fiber:

Multimode 850nm

:

3 dB loss per km on 62.5/125µm cable*

Multimode 1310nm

:

2 dB loss per km on 62.5/125µm cable*

Single Mode 1310nm

:

0.5 dB loss per km on 9/125µm cable*

Single Mode 1550nm

:

0.25 dB loss per km on 9/125µm cable*

5. Optic Cable Types

Conventionally, fiber optic cable with 

yellow-colored

 insulation is used for Single Mode applications; 

gray

or orange-colored

 insulated cable is for Multimode use.  If Multimode cable is used in a Single Mode

application, the test results could be erroneous and confusing.

6. Calculating the Loss on the Fiber

The fiber optic link and/or connectors are frequently the source of various problems.  Check out the
connectors and the integrity of the link first.  Ideally, the link should be calibrated for total loss after the
installation has been completed.  This will accomplish two things: (1) it will verify that the total loss of the link
is within the loss budget of the device and (2) it will provide a benchmark for future testing.  For example,
a system that has been tested as having 6dB total loss when installed and suddenly tests out as having a loss
of 10dB probably has a connector or link problem.

*These numbers are listed for reference only.  We recommend an OTDR reading be used to determine actual link loss.

Summary of Contents for TC3301

Page 1: ...e g network bridges switches or workstation cards to single mode 1300 1550nm or multimode 850nm fiber optics Completely transparent to the network the TC3301R S is ideal for integrating UTP and fiber...

Page 2: ...r 6 0 dBm 1310nm Receiver PIN Diode typical Sensitivity 16 0 dBm 1310nm Optic saturation level 0 dBm 1310nm Loss Budget Multimode 50 or 62 5 125 m 1310nm 10 dB Distance Multimode 50 or 62 5 125 m 1310...

Page 3: ...1550nm Loss Budget Single Mode 9 125 m 1550nm 32dB Distance Single Mode 9 125 m 1550nm up to 120km distance Wavelength Single Mode 1550nm LASER Connector ST FC SC Single One Fiber 40km Model Transmitt...

Page 4: ...ults could be erroneous and confusing 6 Calculating the Loss on the Fiber The fiber optic link and or connectors are frequently the source of various problems Check out the connectors and the integrit...

Page 5: ...dicates the correct operating voltage is being derived from the power source Full Duplex LED indicator Solidly lit when Ethernet signal is in 1000M full duplex mode Link LED indicator Solidly lit when...

Page 6: ...he example diagrams shown on page 7 For example on diagram C the local TC3301 s optic Tx should be connected to the remote network device s optic Rx and vice versa E After step D the FO LED should lig...

Page 7: ...m switch is not closed it indicates an internal problem with the unit For assistance please contact the Technical Support Department at TC Communications 949 852 1973 Electrical Problem If the LNK or...

Page 8: ...onnect the local TC3301 s Tx to the remote TC3301 s Rx and vice versa C Copper to Fiber Connect the optical cables according to the diagram below the local TC3301 s optic Tx should be connected to the...

Page 9: ...n may first inspect such goods at the premises of the Buyer or may give written authorization to Buyer to return the goods to TC Communications Inc transportation charges prepaid for examination by TC...

Reviews: