background image

                                                 

M12-100 Lithium Battery User Manual 

16 

4. Battery maintenance 

4.1 General description 

  Before  cleaning  and  maintaining  the  lithium  battery,  be  sure  to  disconnect  all  loads  and 

charging equipment from the lithium battery. 

 

Before cleaning and maintenance of the lithium battery, please put a protective cover on the 
terminal to prevent the risk of short circuit caused by contacting the terminal during cleaning 
and maintenance.

 

Do not try to open or disassemble the lithium battery!

 

4.2 Security check 

  Check the connection point for loose or broken wires, cracks, deformation, leakage, or other 

types of damage. If the lithium battery is found to be damaged, it must be replaced in time. It 
is forbidden to charge or use damaged lithium batteries. Do not touch the liquid leaked from a 
ruptured lithium battery. 

 

In order to enable the BMS to calculate the SOC of the lithium battery more accurately and 
eliminate  the  cumulative  error  of  the  SOC,  it  is  recommended  to  complete  a  full  discharge 
(discharge to 0% SOC) and full charge (charge to 100% SOC) every 3 months.

 

4.3 Surface clean 

If you need to clean the lithium battery, please wipe the outer surface of the lithium battery with a 
soft,  dry  cloth  or  paper  towel.  Do  not  use  liquids,  solvents  or  abrasive  tools  to  clean  lithium 
batteries. 

Do not try to open or disassemble the lithium battery!

 

4.4 Not used for a long time 

 

If you don’t use the battery for a long time, you need to turn the rocker switch on the MEH-B to 
"O", or turn the Power switch on the lithium battery to "OFF" to turn off the lithium battery to 
avoid damage caused by over-discharge of the battery. 

  When  the  battery  is  not  in  use  for  a  long  time,  it  needs  to  be  charged  to  80%  capacity 

regularly, and the charging cycle is required to be less than 3 months. 

4.5 Use the battery in a low temperature environment 

  When the cell temperature is 

≤2

, the lithium battery will report a low temperature fault alarm, 

and the user cannot directly charge the lithium battery. In the low temperature environment, 
when  the  external  charger  is  turned  on  (charging  voltage  14~14.2V),  the  lithiumbattery  will 
automatically turn on the heating function. After the automatic heating of the lithium battery is 
completed, the battery can be charged normally and the battery low temperature alarm will be 
released. For M12 -100 it will take about 90 minutes to heat from -20°C to a temperature that 
allows charging. 

4.6 Over-discharged o battery 

The battery will be shut down if it hits protection threshold value of over-discharged and without 
being charged in 10 minutes. To wake up battery, you can turn the battery switch or rocker switch 
of MEH-B OFF and then ON. Please charge the battery in 10 minutes if its waken up. 

If he battery is failed to be waken up, please charge the battery directly with charge voltage 14.0V 
or  greater.  The  battery  will  wake  itself  up  and  start  charging  as  long  as  it  measures  voltage  of 
14.0V or greater. 

 

Summary of Contents for M12-100

Page 1: ......

Page 2: ...M12 100 Lithium Battery Module User Manual...

Page 3: ...M12 100 Lithium Battery Module User Manual WARNING HIGH VOLTAGE IN SIDE CAUTION THE DC FUSE MUST HAVE BEENTURNED OFF BEFORE SERVICING MADE IN CHINA...

Page 4: ...all series of battery packs are prohibited from being connected in series Please ensure that the electrical parameters of the related equipments are compatible with each other before use If the long t...

Page 5: ...ional 6 2 5 3 MEH B display panel optional 7 2 5 4 Remote battery switch optional 8 3 Product installation 9 3 1 General description 9 3 2 Unpacking inspection 9 3 3 Positioning and perforation 10 3 4...

Page 6: ...4 2 Security check 16 4 3 Surface clean 16 4 4 Not used for a long time 16 4 5 Use the battery in a low temperature environment 16 4 6 Over discharged o battery 16 5 Storage 17 6 Transportation 17 7...

Page 7: ...e polarities of the lithium battery and the charging and discharging equipment are correctly connected It is forbidden to use lithium batteries of different manufacturers models capacities and types i...

Page 8: ...management and single cell balance function Supports maximum 200A discharge current Refer to Chapter 8 for detailed parameters Supports up to 8 units in parallel so that the total capacity can reach...

Page 9: ...0 Lithium Battery User Manual 3 2 3 Product dimensions Figure 2 1 Picture of M12 100 Figure 2 2 Dimensions of M12 100 2 4 External interface definition Figure 2 3 M12 100 external interfaces A B C D E...

Page 10: ...for details D CAN RS485 External communication port External communication port support CAN and RS485 communication E Display MEH B interface MEH B display interface F Battery Switch Remote switch int...

Page 11: ...F OFF Flashing1 SOC 0 OFF OFF OFF OFF Flashing1 Charging SOC 100 ON ON ON ON ON 75 SOC 100 ON ON ON Flashing2 ON 50 SOC 75 ON ON Flashing 2 OFF ON 25 SOC 50 ON Flashing2 OFF OFF ON 0 SOC 25 Flashing2...

Page 12: ...to install 1 To connect the fuse please follow the steps below Step 1 Open the protective cover of the fuse holder as shown in Figure 2 5 Figure 2 5 Open the protective cover of the fuse holder Step 2...

Page 13: ...2 5 3 MEH B display panel optional An external MEH B display panel can be used as the display unit of the lithium battery which can display the current operating information of the lithium battery It...

Page 14: ...2 5 4 Remote battery switch optional The remote battery switch can be connected to the Battery Switch interface and the battery can be turned on and off through the remote battery switch Figure 2 10...

Page 15: ...hium batteries of the same brand model cycle life capacity and SOC status 3 2 Unpacking inspection Check whether the lithium battery is in good condition after unpacking If the lithium battery is dama...

Page 16: ...positioning requirements in Figure 3 1 Figure 3 1 Installation positioning requirement 3 4 Installation fixed Before use the lithium battery must be effectively fixed and cannot be fixed upside down T...

Page 17: ...Cable requirements Recommended wire diameter Recommended length Recommended color Recommended terminal L1 50mm2 2 5m Red 50 8 copper terminal L2 50mm2 0 5m Red 50 8 copper terminal L3 50mm2 3m Black...

Page 18: ...the lithium battery terminal Step 6 Connect the cable L3 between the terminal of the load or charger and the terminal of lithium battery Torque requirement 12N m Make sure the wiring is tight and fir...

Page 19: ...rallel connection diagram The maximum number of lithium batteries in parallel is 8 To ensure the current sharing of lithium batteries in parallel please follow the installation and wiring requirements...

Page 20: ...L6 positive between the lithium batteries Torque requirement 12N m Make sure the wiring is tight and firm Step 3 Connect the cable L1 between the fuse and the terminal of the load or charger Torque re...

Page 21: ...or provided by TBB 3 6 4 Power ON and Power OFF Power ON the battery please turn the rocker switch on the MEH B to the I position Power OFF the battery please turn the rocker switch on MEH B to O posi...

Page 22: ...time If you don t use the battery for a long time you need to turn the rocker switch on the MEH B to O or turn the Power switch on the lithium battery to OFF to turn off the lithium battery to avoid...

Page 23: ...ase disconnect all loads and chargers connected to the lithium battery Please disconnect the Battery Switch and MEH B from the lithium battery Please cover the terminal protection cover Every 3 months...

Page 24: ...ium battery Check whether the charger is operating normally If all the above are normal please contact your dealer 4 Low voltage protection of the battery The battery capacity is very low please conne...

Page 25: ...the charger and increase the temperature of the lithium battery by heating the internal heating film of the lithium battery If the problem still cannot be solved please contact your dealer 10 Charging...

Page 26: ...t suitable for operation in such a low ambient temperature and the ambient temperature for battery installation is preferably above 30 C If the above is normal please contact your dealer 14 External i...

Page 27: ...ent 150A 30minutes 200A 13minutes Cell operating temperature charging 2 60 Cell operating temperature discharging 30 60 Storage temperature range 1 month 20 45 20 80 SOC 65 RH Storage temperature rang...

Page 28: ...M12 100 Lithium Battery User Manual 22...