15
3.6.3 Communication cable wiring
Step 1: Connect the communication cable L8 between lithium batteries (1#~4#);
Step 2: Please use UTP standard network cable to connect the CAN/RS485 communication
interface of the 1# lithium battery and the corresponding interface of the inverter or system.
Step 3: Please connect the Display communication interface of the #1 lithium battery to the
MEH-B display communication interface.
Note: If you use the MEH-B display panel, do not connect to the dry contact connector
(provided by TBB).
3.6.4 Power ON and Power OFF
Power ON the battery: please turn the rocker switch on the MEH-B to the "I" position;
Power OFF the battery: please turn the rocker switch on MEH-B to "O" position;
3.7 Disconnect the lithium battery
Step 1: Please disconnect the Battery Switch from the lithium battery.
Step 2: Please turn off all devices or chargers connected to the lithium battery.
Step 3: Please disconnect the cables between the negative pole of the lithium battery and the load
or charger.
Step 4: Please disconnect the cables between the positive pole of the lithium battery and the load
or charger.
Note: If you use the MEH-B display panel, you need to disconnect the network cable between the
MEH-B and the lithium battery.