Energier Apollo User Manual
TBB Power Co.
,
Ltd
19
5
500AH
6
600AH
7
700AH
8
800AH
9
≥900AH
In case you choose ≤50AH, the charge current was 7.5A.
In case you choose ≥900AH, the charge current was the max charging current.
The max charging current of the model you are using can only deliver is its max charging current
as specified in data no matter how big battery you selected.
In case you want to charge your battery faster, you could set bank one gear larger to get higher
charging current. However, please make sure the current did not exceed 0.2C (20% of battery
capacity).
For example, for model CH1035L with battery capacity of 12V/200AH.
If you choose battery capacity at 100AH, you could get charging current of 15%x100AH=15A
If you want to charge faster, you could choose 200AH, you could get charging current
15%x200AH=30A.
For example, for model CH2040M with battery capacity of 24V/400AH.
Since the max charging current of this model is 40A, you will get 40A. Not 0.15C, 60A.
The default setting was position 0 (≤50AH)
Please refer to following chart for all setting of DIP Switch:
DIP
Switch
1
2
3
4
5
6
7
8
Work
Mode
Solar
Mode
LVD
Battery Type
EQ
P.S.
Grid
Charger