25
Models 150, 152, 162, 168
Troubleshooting Guide
PROBLEM
PROBABLE CAUSE
REMEDY
6.
Excessive leakage in rear drip
pan.
a. A worn or defective o-ring is on
the beater drive shaft.
a. Replace o-rings every 3 months.
b. The rear shell bearing is worn.
b. Replace the rear shell bearing.
c. Incorrect lubricant was used.
c. Use food grade lubricant
(example: Taylor Lube).
d. Inadequate lubrication of beater
drive shaft.
d. Lubricate the beater drive shaft
properly.
7.
The draw valve is leaking.
a. Incorrect lubricant was used.
a. Use food grade lubricant
(example: Taylor Lube).
b. Worn or defective o-rings are on
the draw valve.
b. Replace o-rings every 3 months.
c. Inadequate lubrication of draw
valve.
c. Lubricate the draw valve properly.
8.
Product is not feeding into the
freezing cylinder.
a. The mix level is inadequate in the
mix hopper.
a. Fill the mix hopper with mix.
9.
The unit goes out on overload
excessively.
a. There are too many appliances
plugged into the circuit.
a. A separate 20 amp. circuit is
needed for the freezer to operate
properly.
b. An extension cord has been
placed between the power cord
and the wall receptacle.
b. If the extension cord is used, it
must match the power cord in
size of circuit ampacity.
10. Models 162 and 168:
Mix from one freezing cylinder
bleeds over to the second
cylinder.
a. The center draw valve seal is
worn, or is improperly lubricated.
a. Lubricate properly and replace
seal every 3 months.
11. Compressor does not run.
a. Control switches.
a. Place switches in correct position
for compressor operation.
b. Fuse blown or circuit breaker.
b. Replace fuse or turn breaker on.
c. Tripped overload.
c. Allow to cool. Check for high head
pressure, tight bearings, stuck
pistons, clogged air cooled
condenser.
d. Compressor contactor in open
position.
d. Repair or replace the contactor.
e. Faulty capacitor relay.
e. Replace the relay.
12. Compressor will not start. Hums
intermittently. Cycling on
overload.
a. Improperly wired.
a. Check wiring against diagram.
b. Low line voltage.
b. Check main line voltage. Locate
the voltage drop.
c. Open starting capacitor.
c. Replace the starting capacitor.
d. Faulty capacitor relay.
d. Replace the relay.
Summary of Contents for Taylormate 150
Page 2: ......
Page 18: ...14 Controls and Systems Models 150 152 162 168 130521 Refrigeration Schematic Figure 5 ...
Page 35: ...31 Models 150 152 162 168 Parts Notes ...
Page 36: ...32 Parts Models 150 152 162 168 160210 Model 150 Exploded View Figure 9 ...
Page 40: ...36 Parts Models 150 152 162 168 160210 Model 152 Exploded View Figure 12 ...
Page 42: ...38 Parts Models 150 152 162 168 Model 162 Exploded View Figure 13 ...
Page 46: ...42 Parts Models 150 152 162 168 Model 168 Exploded View Figure 16 ...
Page 72: ...Model 150 152 050416 12 11 15 Taylor Company 2015 Carrier Commercial Refrigeration Inc c ...
Page 73: ...Model 150 152 050416 27 11 15 Taylor Company 2015 Carrier Commercial Refrigeration Inc c ...
Page 74: ...Model 150 152 050416 40 11 15 Taylor Company 2015 Carrier Commercial Refrigeration Inc c ...