![Taylor Horizon 8752 Operator'S Manual Download Page 10](http://html2.mh-extra.com/html/taylor/horizon-8752/horizon-8752_operators-manual_3810946010.webp)
6
Models 8752, 8756, 8757
Safety
130819
S
Supply cords used with this unit shall be
oil-resistant, sheathed flexible cable not
lighter than ordinary polychloroprene or other
equivalent synthetic elastomer-sheathed cord
(Code designation 60245 IEC 57) installed
with the proper cord anchorage to relieve
conductors from strain, including twisting, at
the terminals and protect the insulation of the
conductors from abrasion.
If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent, or similarly qualified person, in order to
avoid a hazard.
Failure to follow these instructions may result in
electrocution. Contact your local authorized Taylor
Distributor for service.
S
DO NOT
allow untrained personnel to operate
this machine.
S
DO NOT
operate the freezer unless all service
panels and access doors are restrained with
screws.
S
DO NOT
remove any internal operating parts
(example: freezer door, beater, scraper
blades, etc.) unless all control switches are in
the OFF position.
Failure to follow these instructions may result in severe
personal injury from hazardous moving parts.
This unit has many sharp edges that can
cause severe injuries.
S
DO NOT
put objects or fingers in the door
spout. This may contaminate the product and
cause severe personal injury from blade
contact.
S
USE EXTREME CAUTION
when removing
the beater asssembly. The scraper blades are
very sharp.
This freezer must be placed on a level
surface. Failure to comply may result in personal injury
or equipment damage.
Access to the service area of the unit is
restricted to persons having knowledge and practical
experience with the appliance, in particular as far as
safety and hygiene are concerned.
Cleaning and sanitizing schedules are
governed by your state or local regulatory agencies
and must be followed accordingly. Please refer to the
cleaning section of this manual for the proper
procedure to clean this unit.
This machine is designed to maintain product
temperature under 41
_
F (5
_
C). Any product being
added to this machine must be below 41
_
F (5
_
C).
Failure to follow this instruction may result in health
hazards and poor freezer performance.
DO NOT
run the unit without product. Failure to follow
this instruction can result in damage to the unit.
DO NOT
obstruct air intake and discharge openings:
Air cooled units require a minimum of 3” (76 mm) of
clearance around
all
sides of the freezer and 12” (305
mm) on top to allow for adequate air flow across the
condenser(s). Failure to allow adequate clearance can
reduce the refrigeration capacity of the freezer and
possibly cause permanent damage to the compressor.
For Indoor Use Only:
This unit is designed to operate
indoors, under normal ambient temperatures of 70
_
-
75
_
F (21
_
- 24
_
C). The freezer has successfully
performed in high ambient temperatures of
104
_
(40
_
C) at reduced capacities.
NOISE LEVEL:
Airborne noise emission does not
exceed 78 dB(A) when measured at a distance of 1.0
meter from the surface of the machine and at a height
of 1.6 meters from the floor.