C712 Operator Training
-16-
Sanitizing
Step 1
Prepare an approved 100 PPM sanitizing solution (examples: 2-1/2 gal. [9.5 liters] of
Kay-5® or 2 gal. [7.6 liters] of Stera-Sheen®). USE WARM WATER AND FOLLOW
THE MANUFACTURER'S SPECIFICATIONS.
Step 2
Pour the sanitizing solution over all the parts in the bottom of the mix hopper and
allow it to flow into the freezing cylinder.
Note: You have just sanitized the mix hopper and parts; therefore, be sure your hands
are clean and sanitized before continuing with these instructions.
Step 3
While the solution is flowing into the freezing cylinder, take particular care to brush-
clean the mix level sensing probe on the bottom of the hopper, the mix hopper, the
mix inlet hole, the air/mix pump, the pump clip, the mix feed tube, and the locking clip.
Step 4
Install the pump assembly at the rear of the mix hopper. To position the pump on the
drive hub, align the drive hole in the piston with the drive crank of the drive shaft.
Secure the pump in place by slipping the pump clip over the collar of the pump,
making sure the clip fits into the grooves in the collar.
Step 5
Install the pump end of the mix feed tube and secure with the cotter pin. Failure to
follow this instruction could result in sanitizer spraying on the operator.
Step 6
Prepare another pail of approved 100 PPM sanitizing solution (examples: 2-1/2 gal.
[9.5 liters] of Kay-5® or 2 gal. [7.6 liters] of Stera-Sheen®). USE WARM WATER AND
FOLLOW THE MANUFACTURER'S SPECIFICATIONS.
Step 7
Pour the sanitizing solution into the mix hopper.
Step 8
Brush the exposed sides of the hopper.
Step 9
Place the power switch in the ON position.
Step 10
Touch the WASH symbol. This will cause the sanitizing solution in the freezing
cylinder to be agitated. Wait at least 5 minutes before proceeding with these
instructions.
Step 11
With a pail beneath the door spouts, open the draw valve and touch the PUMP
symbol. When a steady stream of sanitizing solution is flowing from the prime plug
opening in the bottom of the freezer door, open the draw valve. Momentarily open the
center draw valve to sanitize the center door spout. Draw off the remaining sanitizing
solution.
Step 12
Once sanitizer stops flower from the door spout, touch the WASH and PUMP symbols
and close the draw valve.
Step 13
Repeat these steps for the other side of the machine.
Summary of Contents for C712
Page 1: ...Model C712...
Page 2: ......