USER INTERFACE
5-7
Models C709 & C717
User Interface
5
Soft Lock
If a Heat Treatment cycle has not been initiated within the
last 24 hours, a soft lock failure occurs. A soft lock allows
the operator to correct the cause of the soft lock. The
operator has the option of either starting another Heat
cycle or brush-cleaning the machine. When a soft lock
occurs, the machine goes into the Standby mode. The
following screen appears. The reason for the soft lock is
indicated on the third line.
If the reason for the soft lock has been corrected,
selecting HEAT CYCLE initiates a Heat cycle
immediately. Selecting BRUSH CLEAN hard locks the
machine, and brush-cleaning is necessary.
The following table lists the variable messages for soft
lock failures that appear on the third line of the screen.
Table 5-1
If the following screen appears, a soft lock has occurred
during the Heat Treatment cycle:
A soft lock can also occur anytime during operation when
the hopper or freezing cylinder temperature rises above
59°F (15°C), the temperature rises and remains above
45°F (7°C) for more than 1 hour, or the temperature rises
and remains above 41°F (5°C) for more than 4 hours.
If a product over temperature condition occurs during
operation, the following screen appears.
When this screen appears, automatic freezer operation
cannot take place until the freezer is disassembled and
brush-cleaned or has completed a Heat Treatment cycle.
Once the freezer is unlocked by starting a Heat
Treatment cycle, the Heat Cycle key illuminates and the
following message appears on the screen:
If BRUSH CLEAN is selected to clear the lockout by
brush-cleaning the machine, the FREEZER LOCKED
message remains on the display until the brush-clean
requirements are fulfilled. The freezer must be
disassembled to activate the 5-minute timer on the
screen. Once the timer counts down to zero, the lockout
is cleared.
To restore the message that identified the reason for the
soft lock, turn the power switch off for 5 seconds, and
then return the power switch to the ON position. The
original message with the reason for the soft lock
appears.
Message
Description
Power Switch Off
Power switch was in the
OFF position.
Mix Out Present
There was a Mix Out
condition present.
Auto Or Standby Off
The machine was not in
the Auto or Standby
mode.
No Heat Cycle Tried
A Heat Treatment cycle
was not attempted in the
last 24 hours. (AUTO
HEAT TIME was
advanced, or a power
loss was experienced at
the time the cycle was to
occur.)
NO HEAT CYCLE START
REASON
>
HEAT FOR HEAT CYCLE
WASH TO BRUSH CLEAN
HEAT TREAT FAILURE
FREEZER LOCKED
>
HEAT FOR HEAT CYCLE
WASH TO BRUSH CLEAN
PRODUCT OVER TEMP
>
HEAT FOR HEAT CYCLE
WASH TO BRUSH CLEAN
DO NOT DRAW
FREEZER LOCKED
Summary of Contents for C709
Page 8: ...1 4 TO THE INSTALLER Models C709 C717 To the Installer 1 Notes...
Page 36: ...5 16 USER INTERFACE Models C709 C717 User Interface 5 Notes...
Page 50: ...6 14 OPERATING PROCEDURES Models C709 C717 Operating Procedures 6 Notes...
Page 56: ...8 4 TROUBLESHOOTING GUIDE Models C709 C717 Troubleshooting Guide 8 Notes...
Page 58: ...9 2 PARTS REPLACEMENT SCHEDULE Models C709 C717 Parts Replacement Schedule 9 Notes...
Page 62: ...10 4 LIMITED WARRANTY ON EQUIPMENT Models C709 C717 Limited Warranty on Equipment 10 Notes...
Page 66: ...11 4 LIMITED WARRANTY ON PARTS Models C709 C717 Limited Warranty on Parts 11 Notes...