background image

Replace syrup pump tubes 

(continued)

 

 

©McDonald’s Corporation · Planned Maintenance Manual · Revised April, 2010 

Page 2 of 4

 

Ta

ylor Company Milkshake and Soft-serv

e Machine Model C602 

Annually 

SS 1 A1

 

Place syrup line and valve in 
bucket. 

Hang the syrup line and valve 
into the empty bucket. 

 

Start flow of SolidSense APSC 
solution though syrup line. 

Press the calibration key 

 

on the control panel to display 
the menu options. Touch the 
auto key

 

 

to move the ar-

row to “syrup prime.” Touch 

the calibration key 

 again 

to display the syrup prime 
screen. Press the flavor select 
key

 

 

for the corresponding 

flavor to start the flow of 
APSC through the line. 

 

Flush syrup line with 
SolidSense APSC. 

Allow the APSC solution to 
continue to flow into the 
empty bucket until all the 
syrup is flushed from the line. 
When the liquid from the 
syrup line runs clear, the line 
is completely flushed. 

 

Pump all liquid from syrup 
line. 

Remove the syrup feed tube 
from the bucket of APSC 
solution and continue to run 
the pump until APSC solution 
no longer runs from the syrup 
line. 
 
Touch the flavor select key 

 

to stop the flow of APSC 

through the syrup line. 

 

10 

Place feed tube in KAY-5 
Sanitizing solution. 

Place the syrup feed tube in a 
bucket of sanitizing solution. 

 

Sanitizing Solution 

 

11 

Place empty bucket under 
milkshake draw valve. 

Place a clean plastic bucket 
under the milkshake draw 
valve.   

 

 

12 

Flush syrup line with KAY-5 
Sanitizing solution. 

Repeat steps 8 through 10 
using the sanitizing solution. 

 

13 

Turn off and unplug machine. 

Move the power switch to the 
off position. Unplug the ma-
chine. 
 

 

 

Do not begin working with 
the syrup pump until the ma-
chine is turned off and 
unplugged. 

 

14 

Remove pump cover tray. 

Remove the pump cover tray 
in the cabinet by lifting it up 
and out. Set it aside. 

 

15 

Open pump. 

Open the pump for the corre-
sponding line by pushing up 
on the hinged cover. The 
pump tube assembly is now 
exposed. 

 

16 

Remove the pump tube. 

Using both hands, grasp the 
pump tube assembly on both 
ends and pull it up and out of 
the pump body. 

 