Replace syrup pump tubes
Annually
SS 1 A1
©McDonald’s Corporation · Planned Maintenance Manual · Revised April, 2010
Page 1 of 4
Ta
ylor Company Milkshake and Soft-serv
e Machine Model C602
Annually
SS 1 A1
Why
To break the bacteria cycle and to ensure proper flow of syrup to the draw valve
Time required
5 minutes to prepare
20 minutes to complete
Time of day
At open
For 24-hour restaurants: during breakfast menu
Hazard icons
Tools and supplies
Bucket, SolidSense™ All
Purpose Super
Concentrate (APSC)
Bucket, KAY-5®
Sanitizing Solution
Bucket, plastic
Bucket, clean and
sanitized towels
Bucket, soiled towels
Plastic wrap
Pump tube
Taylor Lube HP
Procedure
1
Remove syrup feed tube and
syrup jug.
Open the cabinet door. Re-
move the syrup feed tube
from a syrup jug. Wipe the
outside of the feed tube with a
clean, sanitized towel.
Remove the syrup jugs from
the cabinet.
Sanitizing Solution
2
Cover jug with plastic wrap.
3
Place syrup feed tube in
SolidSense APSC solution.
Place the syrup feed tube in a
bucket of APSC solution.
APSC Solution
4
Place empty bucket under
milkshake draw valve.
Place a clean plastic bucket
under the milkshake draw
valve.
5
Remove syrup line from
milkshake freezer door.
Disconnect the corresponding
syrup line from the milkshake
freezer door by raising the
syrup valve retainer. Pull the
valve straight out.