6-8
OPERATING PROCEDURES
Models 8752, 8756, and 8757
Operating Procedures
6
16. Slide the pump collar upwards into the grooves on
the side of the face plate and secure the air/mix
pump in place by slipping the retaining pin through
the crossholes of the pump collar.
Figure 6-32
Note:
Alignment of the air/mix pump is extremely
important. Severe and costly damage may occur if it
is not properly aligned.
17. Lubricate both sides of the pressure switch
diaphragm.
Figure 6-33
18. Place the diaphragm on the front face of the pressure
switch housing. The lubricant will act as an adhesive
to hold the diaphragm in place.
Note: Do Not
place the diaphragm in the pressure
switch cap.
19. Screw the cap onto the housing securely.
Figure 6-34
20. Repeat Steps 1 through 8 for the other side of the
machine on Models 8756 and 8757.
Apply the appropriate
Taylor approved food safe lubricant.
Summary of Contents for 8757
Page 14: ...3 4 SAFETY Models 8752 8756 and 8757 Safety 3 Notes...
Page 28: ...5 4 USER INTERFACE Models 8752 8756 and 8757 User Interface 5 Notes...
Page 52: ...9 2 PARTS REPLACEMENT SCHEDULE Models 8752 8756 and 8757 Parts Replacement Schedule 9 Notes...
Page 58: ...11 4 LIMITED WARRANTY ON PARTS 8752 8756 and 8757 Limited Warranty on Parts 11 Notes...