26
Troubleshooting
Model 430
Troubleshooting Torque Components
Figure 5
A. A missing or worn guide bearing will cause
uneven movement of the rotor system, and will
result in product inconsistencies (too stiff/too
thin). If product becomes too stiff, the door,
torque arm, torque rotor and torque lever may be
damaged.
B. Any distortion or incorrect assembly of the torque
rotor will damage the torque components.
C. If incorrectly sized, damaged or improperly
lubricated o-rings are used, the rotor, door,
torque arm, torque rotor and torque lever may be
damaged.
D. If the torque arm is missing, the product will
freeze and the pulley belt will begin slipping. The
beater reset will then deactivate freezer
operation. In addition, torque components may
be damaged.
Summary of Contents for 430 Torque
Page 2: ......
Page 9: ...5 Model 430 Introduction Figure 1...
Page 16: ...12 Systems and Controls Model 430 080522 Refrigeration System Figure 2...
Page 23: ...19 Model 430 Systems and Controls Mix Level Control Diagram Thermistor Units Figure 4...
Page 24: ...20 Systems and Controls Model 430 Notes...
Page 32: ...28 Troubleshooting Model 430 Notes...
Page 36: ...32 Parts Model 430 140425 Model 430 Exploded View Figure 8...
Page 57: ...430 Thermistor 049345 12...