7
Model 430
Introduction
150210
General Installation Instructions
The following are general installation instructions. For
complete installation details, please see the check out
card.
ALL WIRING AND PLUMBING MUST
CONFORM TO NATIONAL AND LOCAL CODES.
Site Preparation
Review the area the unit is to be installed in before
uncrating the unit. Make sure that all possible hazards
the user or equipment may come into have been
addressed.
Clearance: Air Cooled Units
Air cooled units require a minimum of 3” (76.2 mm) of
clearance around all sides of the freezer. Failure to
allow for adequate clearance can reduce the
refrigeration capacity of the freezer and possibly
cause damage to the compressor.
For Indoor Use Only:
This unit is designed to operate
indoors, under normal ambient temperatures of 70
_
-
75
_
F (21
_
- 24
_
C). The freezer has successfully
performed in high ambient temperatures of
104
_
(40
_
C) at reduced capacities.
This unit must
NOT
be installed in an area
where a water jet or hose can be used.
NEVER
use a
water jet or hose to rinse or clean this unit. Using a
water jet or hose on or around this equipment may
result in electrocution to the user or damage to the
equipment.
This unit must be installed on a level surface
to avoid the hazard of tipping. Extreme care should be
taken in moving this equipment for any reason.
Two or more people are required to safely move this
unit. Failure to comply may result in personal injury or
equipment damage.
Uncrate the machine. Inspect the unit for damage.
Report any damage to the Taylor factory immediately.
This piece of equipment is made in the USA and has
USA sizes of hardware. All metric conversions are
approximate and vary in size.
Installer Safety
In all areas of the world, equipment should be
installed in accordance with existing local codes.
Please contact your local authorities if you have any
questions.
Care should be taken to ensure that all basic safety
practices are followed during the installation and
servicing activities related to the installation and
service of Taylor equipment.
S
Only authorized Taylor service personnel
should perform installation and repairs on
the equipment.
S
Authorized service personnel should consult
OSHA Standard 29CFRI910.147 or the ap-
plicable code of the local area for the in-
dustry standards on lockout/tagout proced-
ures before beginning any installation or
repairs.
S
Authorized service personnel must ensure
that the proper PPE is available and worn
when required during installation and ser-
vice.
S
Authorized service personnel must remove
all metal jewelry, rings, and watches before
working on electrical equipment.
THIS UNIT HAS MANY SHARP EDGES
THAT CAN CAUSE SEVERE INJURIES.
Examples:
S
scraper blades
S
condenser fins
Summary of Contents for 430 Torque
Page 2: ......
Page 9: ...5 Model 430 Introduction Figure 1...
Page 16: ...12 Systems and Controls Model 430 080522 Refrigeration System Figure 2...
Page 23: ...19 Model 430 Systems and Controls Mix Level Control Diagram Thermistor Units Figure 4...
Page 24: ...20 Systems and Controls Model 430 Notes...
Page 32: ...28 Troubleshooting Model 430 Notes...
Page 36: ...32 Parts Model 430 140425 Model 430 Exploded View Figure 8...
Page 57: ...430 Thermistor 049345 12...