BT- 434 Rev.A
12
Gas Withdrawal Circuit
The gas withdrawal circuit vaporizes cryogenic liquid and warms it to ambient temperature for use
in the final application. Opening the gas withdrawal valve (V-3) allows liquid, driven by the pressure
within the vessel, to flow through the vaporizer (VC-1). The vaporizer uses heat from the ambient air
to convert the liquid into a gas and warm it. The vaporizer, like the pressure building coil, is attached
to the inside surface of the vacuum jacket. The vaporizer is located in the upper ¾ of the jacket, the
pressure builder in the lower ¼.
Gas Withdrawal Circuit
Figure 5-Gas withdrawal circuit highlighted in blue.
V-3
CN-4