46
47
©2022 TAXA INC. v.4.2.010122
©2022 TAXA INC. v.4.2.010122
PLUMBING
Shower Hose
(SP-S17)
Sprayer
(SP-S02)
1/2” OD, 3/8” ID
LLDPE Tube
(LN-T11)
1/2” OD, 3/8” ID
LLDPE Tube
(LN-T11)
12mm OD, 9mm
ID LLDPE Tube
(SP-R11)
Elbow, 1/2”
Tube
(SP-R04)
1/2” Female to
1/2” Tube
(SP-R03)
Elbow, Blue,
12mm Tube
(LP-P39)
Faucet
(LP-P22)
Water Pump
(SP-M36)
Ext Shower
(SP-S16)
Water Inlet,
Pressure
Reducing
(SP-M37)
Elbow, Black,
1/2” Tube
(SP-R13)
Filter
(SP-I16)
Sink
(LP-P20)
Water Heater
Furnace Combo
(LP-P25)
1/2” BSPP to
12mm Tube
(SP-R12)
1/2” Male BSP
to 1/2” Tube
(SP-R19)
Tee, 1/2” Tube
(SP-R09)
Elbow, Red,
12mm Tube,
Check Valve
(LP-P40)
Safety
Pop-Off/Drain
(LP-P39)
Shut Off Valve
(SP-R05)
1/2” Check Valve
(SP-R21)
Shower Faucet
(MA-R02)
Pressure Reducer
(SP-D34)
Furnace Water
Heater
22”
From
Fresh Tank
Below
Chassis
Safety
Pop-Off/Drain
Pressure
Reducer
Water Pump
Faucet
Sink
Strainer
Furnace Water Heater
Truma Tube
Below Chassis
28”
34”
2.5”
1/2”
1/2”
1/2”
1/2”
12mm
1/2”
12mm
1/2”
1/2”
1/2”
1/2”
1/2”
CLOSED
OPEN
OPEN
1/2”
1/2”
1/2”
1/2”
1/2”
1/2”
1/2”
1/2”
1/2”
1/2”
1/2”
1/2”
1/2”
1/2”
1/2”
1/2”
1/2”
1/2”
1/2”
2.5”
3.25”
6”
13”
28”
3”
6”
6.5”
2.5”
2”
3”
17”
2.5”
Pressure
Reducing
Water Inlet
7”
Shower
Wand
Shower
7”
7”
1/2”
1/2”
1/2”
1/2”
1/2”
1/2”
1/2”
3.25”
3.25”
10.25”
2.5”
2.5”
PLUMBING
2022 Mantis Kitchen Plumbing System Diagram - WITH Optional Bathroom
Shower
2”
Cut to
3-1/2”
Tailpiece, Cut to 2-1/2”
Tailpiece, Cut to 2”
Shower Strainer
Sink Trap Arm Parts
Shower Trap Arm Parts
Assembled Trap Arm Detail
17” Trap Arm
26-7/8”
A
t P
-T
rap
26-1/2”
A
t T
ee
Floor
Total Slope 3/8”
(1/4” per ft min)
Assembled Trap Arm Detail
24” Trap Arm
5”
A
t P
-T
rap
4-1/2”
A
t T
ee
Floor
Total Slope 1/2”
(1/4” per ft min)
Elbow
Faucet
Sink/Stove
Cut to 10”
Plumber’s Putty
Shower Pan
(MA-R01)
Faucet
(LP-P22)
1-1/2” Extension
Tube, 12”
(SP-D25)
PVC Long Elbow,
1-1/2”
(SP-D38)
1-1/2” Schedule
40 PVC (LN-T22)
1-1/2” P-Trap
Kit
(SP-D22)
Sink Strainer
(SP-H08)
1-1/2” Wall Bend,
7”
(SP-D24)
Stove/Sink
Combo
(LP-P24)
Water Heater
Furnace Combo
(LP-P25)
1-1/2” Tail-piece
(SP-D27)
1-1/2” Slip Flange
(SP-D02)
1-1/2” Sanitary
Diverter Tee
with Baffle
(SP-D15)
1-1/2” Marvel
Connector
(SP-D13)
1-1/2” PVC
Adapter
(SP-D26)
Long Radius Tee
(SP-D39)
1-1/2” Extension
Tube, 6”
(SP-D23)
PVC Short Elbow,
1-1/2”
(SP-D37)
Furnace Water
Heater
14”
Long Elbow
Long Elbow
Long Radius
Tee
Short Elbow
Gray Tank
3”
10”
4”
5-1/4”
3-1/4”
16” Horizontal, Total Slope 1/4” (1/8” per ft min)
4-3/8”
Above Floor
4-5/8”
Above Floor
Trap Arms shall meet NFPA 1192 section 7.4.5. Trap Arm slope to be a min. of 1/4” per ft. per
NFPA 1192 section 7.4.5.1. Drains to be a min. of 1/8” per ft. per NFPA 1192 section 7.4.2.4
2022 Mantis Kitchen Drain System Diagram - WITH Optional Bathroom