23
6 Service & maintenance
This chapter provides information about service and maintenance of the lifters. The chapter is divided
into three sections based on who is to perform the inspections and how often the inspections are to
be carried out. Daily by the operator, quarterly by inhouse maintenance or yearly by TAWI authorised
service technician.
For technical service, maintenance or repairs contact your TAWI representative or [email protected].
TAWI must authorise all modifications to this product. TAWI assumes no responsibility for unauthorised
modifications and guarantees will automatically become invalid if unauthorised modifications have
been made.
Inspections
The following inspections are to be carried out.
• Service must be carried out on a yearly basis.
• If any damage/wear is detected on the lifter, this must immediately be reported to TAWI or au-
thorised TAWI representative. The lifter must be taken out of commission and not be used until
the damage has been repaired.
• All service must be carried out with the battery disconnected. The battery pack can be lifted out
in order to remove the power source.
• In order to deal with the lifter’s cables and wiring, a good knowledge of electricity and TAWI
electrical schedules of the lifters is required.
Daily inspections by operator
1. If yearly service has been carried out, make sure that the service inspection date is valid.
2. Check that the max lifting capacity signs are visible.
3. Check that warning and operating labels are visible.
4. Make sure wheels and bearings are functioning and running smoothly.
5. Make sure breaks are functioning correctly and check for signs of damage/wear.
6. Check external wiring for damage/wear.
7. Make sure that the joystick is functioning properly.
8. Lower the tool (without load) until it hits a surface or object close to the ground to check that the
tipping safety function is working properly.
• If the battery needs to be replaced, either order a new battery pack from TAWI or make sure that
an original battery is used. If assistance is needed, contact TAWI.
• Keep the lifter clean. Do not use chemical cleaners.
Manual CR80 GB update 2019.indd 23
2019-09-11 14:18:44