Installation manual 
PFB-0450-TG 

DISCLAIMER OF LIABILITY 

-  The installation, handling and use of Taurus 

Renovables modules are beyond company 
control. Taurus Renovables does not assume 
any responsibility for loss, damage, injury or 
expense resulting from the improper installati- 
on, handling, use or maintenance. 

-  Taurus Renovables Solar assumes no respon- 

sibility for any infringement of patents or other 
rights of third parties that may result from use 
of the module. No license is granted by implica- 
tion or under any patent or patent rights. 

-  Specifications are subject to change without 

prior notice. 

 

SAFETY PRECAUTIONS 

-  Potentially lethal DC voltages can be gene- 

rated whenever PV Modules are exposed to 
a light source therefore, avoid contact with 
electrically active parts and be sure to isolate 
live circuits before attempting to make or break 
any connections. 

-  Only authorized and trained personnel should 

have access or  perform work on the modules 
or solar system. 

-  When working on electrical connections, remo- 

ve all metallic jewelry, use properly insulated 
tools and wear appropriate personal protective 
equipment to reduce the risk of electric shock. 

-  Do NOT stand or step on, damage or scratch 

the front or backside surfaces of the module. 

-  Broken  modules  cannot  be  repaired  and  cont- 

act with any module surface or frame can lead 
to electrical shock. Do NOT use a module with 
broken glass or torn substrate. 

-  Do NOT disassemble the modules or remove 

any part of the module. 

-  Protect the electrical plug contacts against 

corrosion and soiling. Make sure that all 
connectors are corrosion free and clean before 
making the connection. 

-  Do NOT install or handle modules when they 

are wet or during periods of high wind. 

-  Ensure sure that all connections are securely 

made with no gap between the contacts. Any 
gap can result in electrical arcing that can cau- 

se a fire hazard and/or an electric shock. 

-  Make sure that the polarity of each module or 

a string is not reversed considering the rest of 
the modules or strings. 

-  Do NOT artificially concentrate sunlight on 

these solar modules. 

-  Taurus Renovables Solar modules are certified 

for operating in Class A installations at voltages 
below 1500Vdc. This maximum voltage should 
not be exceeded at any time and, as the volta- 
ge of the module increases, above data sheet 
values, at operating temperatures below 25°C, 
then these need to be taken into account when 
designing a PV system. 

-  Do NOT use water to extinguish fires of an 

electrical origin. 

-  Under normal conditions, a solar photovoltaic 

module is likely to produce more current and / 
or voltage than reported under standard test 
conditions. Accordingly, the value of Isc mar- 
ked on this module should be multiplied by a 
factor of 1.25 when determining the conductor 
current ratings, fuse sizes and size of controls 
connected to the SPV output. 

 

UNPACKING AND STORAGE 

-  At time of receipt, verify that the product deli- 

vered is in fact the product ordered the product 
name, subname, and serial number of each 
laminate are clearly marked on the outside of 
each packing box. 

-  Leave the product in its original packing box 

until you are ready to install. 

-  Store packing boxes in a clean, dry area with 

relative humidity below 85% and ambient tem- 
peratures between -20°C and 40°C. 

-  Do NOT stack more than the maximum amount 

of allowable pallets on top of each other. 

-  At the installation site, take care to keep modu- 

les and particular their electrical contacts clean 
and dry before installation. If connector cables 
are left in damp conditions then the contacts 
may corrode. Any module with corroded cont- 
acts should not be used. 

-  If pallets are stored temporarily outside then 

place a protective covering over the pallet to 
protect it from direct weathering and do not 
stack more than one pallet high. 

-  Two people are required to unpack the mo- 

dules from the packing box, when handling 
modules always use both hands. 

-  Do NOT use a knife to cut the zip-ties, but use 

wire cutting pliers. 

Summary of Contents for PFB-0450-TG

Page 1: ...PFB 0450 TG Panel FULL BLACK Manual instalaci n Installation manual...

Page 2: ......

Page 3: ......

Page 4: ...de acero inoxidable Stainless steel spring washer M4 4 6 Arandela plana de acero inox Stainless steel flat washer M4 5 Arandela de acero inox dentada Stainless steel locck toothed washer M4 7 Arandel...

Page 5: ...71 40 84 40 96 Corriente de potencia m xima Imp Maximum Power Current Imp 10 46 10 54 10 63 10 72 10 81 10 90 10 99 Potencia m xima nominal W Rated Maximum Power W 420 425 430 435 440 445 450 Toleran...

Page 6: ...izar la conexi n NO instale ni manipule m dulos cuando est n mojados o durante per odos de viento fuerte Aseg rese de que todas las conexiones se realicen de forma segura sin espacios entre los contac...

Page 7: ...85RH Presi n de carga mec nica la presi n de dise o es 3600 frontal 1600 posterior y el factor de seguridad es 1 5 NOTAS Los m dulos han sido evaluados por un labo ratorio acreditado para una carga m...

Page 8: ...n t rmica de las estructuras de soporte MONTAJE CON PERNOS El marco de cada m dulo tiene 8 orificios de montaje de 9 mm en una ubicaci n ideal para optimizar la capacidad de manejo de car ga para aseg...

Page 9: ...conexi n a tierra de cobre desnudo recomendado de 10 12 AWG CABLEADO DEL M DULO Todo el cableado debe ser realizado por instaladores calificados de acuerdo con los c digos y regulaciones locales Los m...

Page 10: ...ulos se cargar n mediante la cadena sombreada y la corriente fluir y por lo tanto afecta el n mero de cadenas en paral elo Configuraciones de m dulos en paralelo capacidad de fusible Isc SELECCI N Y C...

Page 11: ...echos de la matriz es una compensaci n entre el costo de la limpieza el aumento de la producci n de energ a como resultado de esta limpieza y el tiempo para volver a ensuciar los m dulos despu s de la...

Page 12: ...or an electric shock Make sure that the polarity of each module or a string is not reversed considering the rest of the modules or strings Do NOT artificially concentrate sunlight on these solar modul...

Page 13: ...production solar modules should normally be mounted facing the equator at an angle to the horizontal plane equivalent to the latitude of the installation In the event that you mount the solar modules...

Page 14: ...ounting method use at least four clamps on each module two clamps should be attached on each long sides of the module for portrait orientation and each short sides of the module for landscape orientat...

Page 15: ...each module refer to product label or data sheet TCvoc Thermal coefficient of open circuit vol tage for the module refer to table add Tmin Minimum ambient temperature The minimum and maximum outer di...

Page 16: ...ed current will flow through the diode and bypass the shaded module thereby minimizing module heating and array current losses Bypass Diode Model 25PV045 MAINTENANCE AND CARE A well designed solar sys...

Page 17: ...ately Contact your installer Contact Taurus Renovables Solar after sales service team at www taurusrenovables com WARNING For any electrical maintenance the PV system must first be shut down Improper...

Page 18: ......

Page 19: ...http taurus home com You can also request related information by contacting us You can download this instruction manual and its updates at http taurus home com Fran ais GARANTIE ET ASSISTANCE TECHNIQ...

Page 20: ...ualiseringen ervan downloaden via http taurus home com Polski GWARANCJA I SERWIS TECHNICZNY Ten produkt jest uznawany i chroniony prawn gwarancj zgodnie z obowi zuj cymi przepisami W celu wyegzekwowan...

Page 21: ...2066776656 Cyprus 20 Bethlehem Str P O Box 20430 2033 Strovolos 35722711300 Czech Republic Milady Horakove 357 4 568 02 Svitavy 420 461 540 130 Democratic Republic AV Pont Canale N 3440 Kinshasa 00243...

Page 22: ...21 Mauritania 134 Avenue Gamal Abdener Ilot D Nouakchott 2225254469 2225251258 Mexico Rosas Moreno N 4 203 Colonia de San Rafael C P 06470 Delegaci n Cuauht moc Ciudad de M xico 52 55 55468162 Montene...

Page 23: ......

Page 24: ...Avda Barcelona s n 25790 Oliana Spain...

Reviews: