7
DATA link
Warning!Read safety information before installing,powering,
Operating or servicing the Cyclone 1320.
A DMX 512 date link is required in order to control the Cyclone 1320 via DMX.
The Cyclone 1320 has 3-pin XLR connectors for DMX data input and output,the pin-out
on all connectors is PIN 1=shield,PIN 2= Cold(-),and PIN 3=hot(+).
Note that if independent control of a fixture is required,it must have its own DMX
channels,fixtures that are required to behave identically can share the same DMX channels.
You may connect up to 4 Cyclone 1320 on one daisy
Chained DMX link,to add more fixtures when the above limit is reached,create a new DMX
universe and another daisy-chained link. Tips for reliable data transmission
Use shielded twisted-pair cable designed for devices:standard microphone cable cannot
transmit control data reliably over long runs.
Connecting the data link
To connect the Cyclone 1320 to data:
Connect the DMX data output from the controller to the closest Cyclone 1320 3-pin XLR
DMX input connector.
Installation
Overhead rigging
The installation of the device has to be built and constructed in a way that it can hold 10
times the weight for 1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment,e.g. an
appropriate catch net,this secondary safety attachment must be constructed in a way that no
part of the installation can fall down if the main attachment fails.
When rigging, servicing the device staying in the area below the installation place,on
bridges,under high working places and other endangered areas is forbidden.
The operator has to make sure that safety-relating and machine-technical installations are
approved by an expert before taking into operation for the first time and after changes before
taking into operation another time.
The operator has to make sure that safety-relating and machine-technical installations are
approved by an expert after every four year in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are
approved by a skilled person once a year.
Procedure:
The device should be installed outside areas where persons may walk by or be seated.
IMPORTANT:OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE,including(but not
limited to)calculating working load limits,installation material being used,and periodic safety
inspection of all installation material and the device,if you lack these qualifications,do not