K206MA
5 - 6
STOP
STOP button N.C. input – Stops the bar in any position, temporar
-
ily preventing the automatic closure, if programmed.
Bridge the
connectors if not used.
(5= STOP - 6= COM )
7 - 8
CLOSE
CLOSE button N.O. input – Controls the total closure of the bar.
(7= COM - 8= CLOSE)
7 - 9
PHOTOCELLS
N.C. photocell input - it cuts in during the closing. Bridge the con
-
nectors if not used.
(7= COM - 9= FOT)
Note: the photocell transmitter must always be supplied by
terminals no. 12 and no. 13, since the safety system test
(phototest) is carried out on it. Without this connection, the
control unit does not work. To override the testing of the
safety system, or when the photocells are not used, set dip-
switch no. 6 to OFF.
7 - 10
SENSITIVE EDGE
SENSITIVE EDGE input (resistive sensitive edge or fixed safety
edge); works only during closing and causes the bar to re-open
totally.
Bridge the connectors if not used.
(7= COMMON - 10= SENSITIVE EDGE)
11 - 12 **
AUX
auxiliary circuits output 18 V DC max. 15 W for photocells, re
-
ceivers, etc...
(11= NEGATIVE - 12= POSITIVE)
12 - 13 **
TX PHOTOCELLS
18V DC output for transmitter photocell – phototest - max. no. 1
photocell transmitters.
(12 = POSITIVE - 13 = NEGATIVE)
14 - 15 **
FLASHING LIGHT
(LED CABINET)
18V DC max. 20W output for flashing light supply, flashing signal
supplied by the control unit, rapid for closing, slow for opening.
(14 = POSITIVE - 15 = NEGATIVE)
16 - 17* **
ELECTROMAGNET
(VANDAL-PROOF)
Output for vandal-proof
18V DC, 3 W max;
Output for electromagnet to be connected to the end of the rod
to hold the barrier closed (vandal-resistant device). With the bar
-
rier closed, the electromagnet is constantly powered. Every time
a command is given, the electromagnet is turned off before the
motor starts running.
(16= POSITIVE - 17= NEGATIVE)
16 - 18* **
BAR LED
bar LED power output.
(16=POSITIVE - 18= NEGATIVE)
19 - 20*
2
nd
CH RADIO
2
nd
radio channel output - for control of an additional automation
or for switching on lights, etc... (N.O. clean contact)
Warning: to connect other devices to the 2nd Radio Channel
(area lighting, pumps, etc.), use an additional auxiliary relay
(see note at end of paragraph).
WARNING: the default outlet is active monostable 2 sec. To
switch it to active bistable or to modify the activation time
it is necessary to use the TAUPROG hand-held programmer
(see relative instructions).
21 - 22
AERIAL
plug-in radio-receiver aerial input , for 433.92 MHz receivers
only. (21 = GROUND - 22 = SIGNAL)
23 - 24 -
28 - 29
MOTOR
motor supply output 18V DC max. 50 W.
(23-28 = POSITIVE - 24-29 = NEGATIVE).
See note below.
25 - 26 - 27
OPTIONAL
ENCODER
encoder supply and input (25 = WHITE signal - 26 = BLUE nega
-
tive - 27 = BROWN positive).
See note below.
30 - 31 - 32
MAIN
ENCODER
encoder supply and input (30 = WHITE signal - 31 = BLUE nega
-
tive - 32 = BROWN positive).
* The outlets can be configured using the TAUPROG (see relative instructions). The standard con
-
figuration is shown in the table.
** If Jumper 6 is not plugged in, energy saving mode will be activated and, at the end of each man
-
ouvre, outputs
11-12, 12-13, 14-15, 16-17
and
16-18
will be switched off.
The terminal board for motor 2 (23-27) is to be used in support of the one for motor 1
(LUXE), or in case of fault/failure of the one for motor 1 (28-32), see wiring diagram.