![tau K127MA Installation Manual Download Page 19](http://html.mh-extra.com/html/tau/k127ma/k127ma_installation-manual_821479019.webp)
19
K127MA
21 - 22
AERIAL
plug-in radio-receiver aerial input , for 433.92 MHz receivers
only. (21= GROUND - 22= SIGNAL)
23 - 24
MOTOR (M2)
motor (M2) supply output 18V DC max. 300 VA.
(23= POSITIVE - 24= NEGATIVE)
See note below.
25 - 26 - 27
ENCODER (M2)
encoder supply and input (25= WHITE signal - 26= BLUE nega
-
tive - 27= BROWN positive)
See note below.
28 - 29
MOTOR (M1)
motor (M1) supply output 18V DC max. 300 VA.
(28= POSITIVE - 29= NEGATIVE)
30 - 31 - 32
ENCODER (M1)
encoder supply and input (30= WHITE signal - 31= BLUE nega
-
tive - 32= BROWN positive)
* The outlets can be configured using the TAUPROG (see relative instructions). The standard configu
-
ration is shown in the table.
The terminal board for motor 2 (23-27) is to be used in support of the one for motor 1 ,
or in case of fault/failure of the one for motor 1 (28-32), see wiring diagram.
IMPORTANT:
•
Do not connect auxiliary relays or other devices tot he 18V DC output (terminals 11 – 12) to
avoid malfunctions of the control unit. Use separated power supply / transformers instead;
•
do not connect switching feeders or similar apparatus close to the automation that may be
a source of disturbance.
LOGIC ADJUSTMENTS
Make the logic adjustments.
Note: when any adjusting devices (trimmers or dip-switches) on the control panel are operated,
a complete manoeuvre must be carried out in order for the new settings to take effect.
TRIMMER
T.R.A.
not used;
T.C.A.
Automatic Closing time adjustment: from about 1 to 120 seconds (see dip-switch
no. 1);
FR.
obstacle detection sensitivity adjustment.
Note: by rotating the TRIMMER FR. clockwise the sensitivity of the gearmotor to
obstacles diminishes
and therefore the thrust force increases
; vice-versa, by rotat-
ing it counter-clockwise, the sensitivity of the gearmotor to obstacles increases
and therefore the thrust force diminishes
.
Dip switch
1
AUTOMATIC
CLOSING
On
when completely open, closure is automatic after the set time on the
T.C.A. trimmer has past.
Off
the closing manoeuvre requires a manual command.
2
2 / 4 STROKE
On
when the automation is operating, a sequence of opening/closing com
-
mands causes the automation to OPEN-CLOSE-OPEN-CLOSE, etc.
Off
in the same conditions, the same sequence of commands causes the
automation to OPEN-STOP-CLOSE-STOP-OPEN-STOP, etc . (step-by
step function) (see also dip switch 4)
.
3
CLOSES AGAIN
AFTER THE
PHOTOCELL
On
after the photocell is activated (input 7 - 9), the automation closes
automatically after 5 seconds.
Off
function off.
4
NO REVERSE
On
the automation ignores the closure command during opening.
Off
the automation responds as established by dip switch No. 2.
5
PRE-
FLASHING
On
the pre-flashing function is enabled.
Off
the pre-flashing function is disabled.
ENGLISH