11
SE, STOP, PEDESTRIAN, etc.), in order to avoid gate malfunctions, it will be neces-
sary to uncouple the various controls using RELAYS or using our 750T-RELE device.
2. TECHNICAL FEATURES
Power input to board
230V AC - 50 Hz
Maximum power of motor
280 W - 230V AC
230 Vac line rapid fuse (F1 - 5x20)
F 6,3A
24 Vac auxiliary delayed fuse (F2 - 5x20)
T 2A
Input voltage of motor circuits
230V AC
Input voltage of auxiliary circuits
24V AC
Input voltage of logic circuits
5V DC
Working temperature
-20 °C ÷ +55 °C
3. TERMINAL BOARD CONNECTIONS
Key:
N.C. = Normally Closed N.O. = Normally Open
Terminals Function
Description
1 - 2
POWER SUPPLY
power input 230 Vac. 1=NEUTRAL, 2=PHASE;
1 - 3
FLASHING LIGHT
flashing light output 230 Vac 50 W max.
Note : the signal is already modulated for direct use;
4 - 5 - 6
MOTOR 2
motor 2 power output, 230 Vac, max. 400 W.
4=CLOSE, 5=OPEN, 6=COMMON.
Note: connect the capacitor between terminals 4 and 5;
6 - 7 - 8
MOTOR 1
motor 1 power output (opens the leaf fitted with the electric lock), 230
Vac, max. 280 W. 6=COMMON, 7=CLOSE, 8=OPEN.
Note: connect the capacitor between terminals 7 and 8;
9 - 10
2
nd
CH RADIO
2nd built-in radio channel output – for commanding another automatic
device or turning on lights, etc. (N.O. no-voltage contact max. 1 A);
Warning: to connect other devices to the 2nd Radio Channel (area
lighting, pumps, etc.), use an additional auxiliary relay.
11 - 12
ELECTRIC LOCK
electric lock power output 12 Vac max. 15 W;
13 - 15
PHOTOCELL TX
transmitting photocell power output (for PHOTO TEST), 24 Vac max. 5
W - max. no. 1 photocell transmitter;
14 - 15
GATE OPEN
WARNING LIGHT
gate open and moving LED power output 24 Vac, max. 3 W;
15 - 16
PHOTOCELL
power output, 24 Vac max. 15 W for photocells – max. 2 pairs (and/or
relays, receivers, etc.);
17 - 18
OPEN/CLOSE
N.O. OPEN/CLOSE button contact input – commands opening and closing
of the gate - governed by dip-switches 2 and 4 (17 = COM -18 = O/C);
17 - 19
PEDESTRIAN
N.O. PEDESTRIAN button contact input – commands total opening and
closing of motor 1 – governed by dip-switches 2 and 4 (17 = COM - 19 = PED);
17 - 20
STOP
N.C. STOP button contact input – if programmed, it stops the gate in
any position and temporarily disables the automatic closing cycle (17 =
COM - 20 = STOP);
17 - 21
PHOTOCELL
N.C. photocell contact input – cuts in during closing or during opening
and closing, see dip-switch 3 (17 = COM - 21 = PHOT);
Note: the photocell transmitter must always be powered by
terminals 13 and 15 as the safety system is tested (Photo test)
through them. The control unit will not work without this
connection. To disable the safety system test, or when photocells
are not used, turn dip-switch 6 OFF.
22 - 23
TRANSFORMER
transformer power output (22 = 0 Vac - 23 = 230 Vac);
ENGLISH