User Manual (English version)_V2.0
42
Appendix III. Recommended Monitoring Parameters Setting Value
i.
Periodic measurement (Automatically Scan) setting
Item
Recommended setting
Auto measuring
ON (BLE Mode)
Measuring Frequency
1 time(s)/hr
Measuring Start Time
current time
ii.
Abnormal temperature setting
App will automatically display the proper value according to [
Insulation class
] in the setting of
[
Motor Information
]. <Experimentation Method>
Insulation class
Coil temperature
(
℃
)
Warning
Danger
℃
℉
℃
℉
Class B
120
50
122
60
140
Class E
130
50
122
60
140
Class F
155
60
140
70
158
Class H
180
85
185
95
203
iii.
Abnormal vibration setting
App will automatically display the proper value according to [
Motor output power
] in setting of
[
Motor Information
].
ISO 10816-1
Motor output power
Warning
Danger
kW
HP
mm/s
in/s
mm/s
in/s
Class I
0 - 15
0 - 20
1.80
0.07
4.50
0.18
Class II
15 - 75
20 - 100
2.80
0.11
7.10
0.28
Class III
75 - up
100 - up
4.50
0.18
11.2
0.44
iv.
Residual Power of Battery & Maintenance time setting
Item
Recommended setting
Residual Power
Warning(%)
Danger(%)
20
10
Next maintenance time
1,000 Hrs