background image

UP051-EN  Nozzle FN-1025 - Instruction and Maintenance Manual_rev2.docx                                                     

 

- 2 -

 

 
 
 

 
2-1. How to use nozzle 

 

1.   Insert the nozzle sufficiently into the fuelling port of the automobile and seal up vapour recovery boot 

with the fuelling port. 

 

2.   Pull the nozzle lever and lock in the latch. Fuelling starts. 

 

3. When the fuel level reaches the pilot hole of the nozzle spout, the main valve of the nozzle closes 

automatically to stop fuelling.  

 

4.   Unlock the nozzle lever from the latch and return to the initial state. It can refuel again if pulling the lever 

once again.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

WARNING

 

 

1.  Do not drop the nozzle onto the ground. The nozzle may be damaged 

and automatic shut off function of the nozzle may not work. 

 
2.  Insert the nozzle deeply into the fuelling port. Otherwise, the nozzle 

may drop by the shock of automatic shut-off. 

 
3.  Depending on the car model, the fuel may pour out before the auto-stop 

is applied due to difference in the fuelling port. In such a case, set the 
nozzle lever to the lower position, and slow down the fuelling speed.  

 
4.  Set the nozzle in the right direction. Automatic shut off function of the 

nozzle may not work properly if refuelling with the sideways or the 
inverse attitude.

 

 

 

 

 

 

Spout 

Lever 

Latch 

Anchor Spring  

Lower position 

First position 

2.  Instruction 

Summary of Contents for ULTRA FN-1025 Series

Page 1: ...NO ULTRAAutomatic Nozzle for Vapour Recovery Fuel Dispenser Nozzle Model FN 1025 series Instruction and Maintenance Manual II 1 G TATSUNO ULTRA automatic nozzle for vapour recovery without swivel TATS...

Page 2: ...to electric shown in this example A general caution is indicated by The circle mark shows banning What is banned is shown inside the circle no fire in this example A general ban is indicated by The b...

Page 3: ...gasoline vapours 2 Turn off cell phones and other electronic devices Electronic devices may ignite gasoline vapours 3 Never pull nozzle lever except when refuelling Never pull nozzle lever unless the...

Page 4: ...container it may cause fire due to static electricity 7 Return nozzle lever securely After fuelling completely return the nozzle lever fully to the initial position Otherwise fuel may pour out when s...

Page 5: ...ustomers to safe place Sprinkle dry sand or the like over the leaking fuel to prevent diffusion Keep fire extinguisher at hand to be ready for fire Prevent entry of vehicles and people to prevent seco...

Page 6: ...x 1 Specification 1 2 Instruction 2 2 1 How to use nozzle 2 2 2 Installation 3 2 3 Testing 4 3 Maintenance 5 3 1 Daily inspection 5 3 2 Periodic inspections 5 4 Trouble Shooting 6 5 Guarantee and Repl...

Page 7: ...tests before leaving the factory Specification Nozzle Model FN 1025 Fuel type used Petrol Spout O D 21mm Vapour inlet type 1 Rubber suction inlet 2 Stainless suction inlet Vapour recovery valve 1 On...

Page 8: ...the lever once again WARNING 1 Do not drop the nozzle onto the ground The nozzle may be damaged and automatic shut off function of the nozzle may not work 2 Insert the nozzle deeply into the fuelling...

Page 9: ...de with new The tightening torque of the screw 60N m 4 Flow test nozzles swivels before putting nozzles swivels in service See testing instructions Reference page 4 WARNING 1 Please read safety instru...

Page 10: ...w rate of the dispenser 3 Automatic shut off test Start flow into approved metal test container place nozzle in first latch position Immerse the sensor on nozzle spout tip below the level of liquid No...

Page 11: ...rding to Testing of 2 3 3 Confirm the pressure controlled safety shut off function of the nozzle according to Testing of 2 3 4 Confirm that the electrical resistance between the nozzle tip and dispens...

Page 12: ...and fill again 3 Some filler necks are difficult to refuel Slow down fuel delivery Put on low latch position Nozzle fails to open 1 Pump pressure is not added to the nozzle Check the pump and solenoi...

Page 13: ...or the quantity of refuelling 2 500 000L If you have any suggestions as to how we can improve the quality and or readability of this manual then we would be happy to hear from you We can be contacted...

Reviews: