UP051-EN Nozzle FN-1025 - Instruction and Maintenance Manual_rev2.docx
- 2 -
2-1. How to use nozzle
1. Insert the nozzle sufficiently into the fuelling port of the automobile and seal up vapour recovery boot
with the fuelling port.
2. Pull the nozzle lever and lock in the latch. Fuelling starts.
3. When the fuel level reaches the pilot hole of the nozzle spout, the main valve of the nozzle closes
automatically to stop fuelling.
4. Unlock the nozzle lever from the latch and return to the initial state. It can refuel again if pulling the lever
once again.
WARNING
1. Do not drop the nozzle onto the ground. The nozzle may be damaged
and automatic shut off function of the nozzle may not work.
2. Insert the nozzle deeply into the fuelling port. Otherwise, the nozzle
may drop by the shock of automatic shut-off.
3. Depending on the car model, the fuel may pour out before the auto-stop
is applied due to difference in the fuelling port. In such a case, set the
nozzle lever to the lower position, and slow down the fuelling speed.
4. Set the nozzle in the right direction. Automatic shut off function of the
nozzle may not work properly if refuelling with the sideways or the
inverse attitude.
Spout
Lever
Latch
Anchor Spring
Lower position
First position
2. Instruction