TOWED VERTICAL MIXER
any other elements that have been damaged while the machine was being
used.
The mixer’s rear reflectors should always be kept clean and in good
condition in those models that only have these devices.
Electric Scale
To assure that the scale operates correctly, keep the following
recommendations in mind:
1.
Avoid knocks to the screen and the cells. Rough hits to the wheels
when travelling on roads in poor conditions can cause the cells to
deteriorate, causing a defective weight reading.
2. Do not allow water to enter the inside of the screen of the scale or the
switchbox.
3. Periodically check and ensure that the weight indicated by the scale
is correct.
4. When any error is observed in the weight, the following should be
checked:
a) That the cables make good contact, and they do not get shorted
due to a poor connection.
b) That the screws and the load sensor clamps are not broken or
bent, causing contact between the tub and the chassis.
c) That the load sensors have not suffered deformations due to
rough hits.
5. Do not handle the switchbox or the load sensors.
Any work done on the weighing system should be done only
and exclusively by specialized TATOMA personnel.