nik STEROWANIE

Wskazanie górnego czujnika CWU

Wskazanie dolnego czujnika CWU

Wskazanie czujnika kominka

CO

*

KOM

?

CWU

80

o

73

o

68

o

12

1.

Control unit status diode: alarm (red), standby (orange), operation (green), manual MAN
(blinking green)

2.

Graphic display

3.

Button F1: switch-on/off power supply

4.

Increase button

5.

Decrease button

6.

Confirmation button

7.

Parameter selection button

8.

Button F2 (ESC - return to the main screen)

The control unit is equipped with the clock, which enables the automatic change of the control unit
operation at different times of day. 24 hrs are divided into 5 time zones (

) . Each zone

has a start time FROM and an end time TO. The same start and end time means the zone isn

t active,

which doesn

t change the settings of the control unit. The time zones can overlap each other in that

case binding are the settings for the active zone of higher number.

is not seen till the following alarm situation takes place:

1. Damage of the T1(BUFFER) sensor. The

text shows up.

2. Damage of the T2(KSL) sensor . The

text shows up.

3. Damage of the T3 sensor of the fireplace. The

text shows

up.

4. The exceeding of

The

text shows up.

5. The exceeding of

The

text shows up.

6. The exceeding of

The

text shows up.

Time zones

$1, $2, $3, e4, e5

BUF temp. sensor (T1) damaged

KSL temp. sensor (T2) damaged

Fplace temp. sensor (T3) damaged

too high temp. of the fireplace

too high temp. of the buffer

too high temp. of the collector

Alarm screen

ALARM

the limit temperature of the fireplace defined by the

parameter.

the limit temperature of the buffer

defined by the

parameter.

the limit temperature of the collector defined by the

parameter.

<21> ALARM Temp.

<24> BUF ALARM

Temp.

<26> ALARM Temp

KSL

3.1

!

3.2 Screens

THIS SOFTWARE VERSION DOES NOT INCLUDE THE TIME ZONES.

Pump P1
230V/50Hz

Pump P2
230V/50Hz

Pump P3
230V/50Hz

+

+

+

0

0

0

VCC
STER

GND

Temperature
sensors

AIR DAMPER

T1

PP

PE

T2

T3

MAINS

230V/50Hz

N N N N

L

1

2

3

L

L

L

N
PE
L

RED

BLUE

BLACK

Fig.3 Electrical wiring diagram

PP Air damper
T1 Temperature sensor of the BUF container (buffer container)
T2 Temperature sensor of the KSL collector (solar collector)
T3 Temperature sensor of the fireplace water jacket FIREPLACE
P1

Pump loading the BUF container from KSL

P2

Pump loading the BUF container from FIREPLACE

P3

CH circulating pump

CONTROL

FUSE

Alarm

text

4 Installing the control unit
!

!
!

!

THE

SHOULD NOT BE EXPOSED TO WATER AFFECTING. ITS

ENVIRONS OUGHT TO BE CLEAN.

THE PRODUCER DOESN'T TAKE ANY RESPONSIBILITY FOR DAMAGES CAUSED BY
WRONG USAGE OF THE

.

Connection diagram of the elements of the control unit is presented on fig. 3

THE CONTROL UNIT IS SUPPLIED BY 230V/50HZ .
ANY MOVES REGARDING INSTALLATION SHOULD BE MADE AT
THE DISCONNECTED MAINS.

THE CONTROL UNIT HAS TO BE CONNECTED TO THE MAINS WITH THE ZERO-PIN.

CONTROL UNIT

CONTROL UNIT

Summary of Contents for RT-08G-BUF-SOLAR

Page 1: ...ion Housing protection class IP41 Fuse 6 3A 250V Number of outputs to control pumps 3 250W 230V 50Hz Number of nonvoltage outputs 1 Number of outputs to control the air damper drive 1 5V 500mA DC Numb...

Page 2: ...tainer from the solar collector KSL P1 The pump of the collector P1 runs if the temperature of the collector T2 exceeds the temperatureofthebuffer T1 bytheparametervalue 64 DeltaKSL The next function...

Page 3: ...p P1 2 4 2 5Summermode CH The collector pump P1 runs if the collector temperature T2 exceeds the buffer temperature T1 by thevalue Exceeding the maximum collector temperature parameter causes the KSLp...

Page 4: ...ver to the screen of the fireplace 12 CONTROL Relay 3 3 2 7 6 4 5 7 6 Fig 2 Control panel view Connection cable of the control may be replaced only by producer or his authorized service locations WARR...

Page 5: ...ce toohigh temp ofthebuffer toohigh temp ofthecollector Alarm screen ALARM the limittemperatureof thefireplace definedbythe parameter the limit temperature of the buffer defined by the parameter the l...

Page 6: ...ION OF THE PREVIOUS PASSWORD IF PRESENT WITHOUT IT BEING EXPOSED PASSWORD OF PRODUCER S SERVICE IS UNIQUE AND IS NOT DEPENDENT ON THE USER S PASSWORD IT SHOUDN T BE EXPOSED TO THE USER INSTEAD OF THAT...

Page 7: ...at which the alarm generates 75 95 o C 85 o C Fireplace temperature T3 at which the alarm turns on 5 25 o C 10 o C Decreasing fireplace temperature in relation to preset temperature at whose exceedin...

Page 8: ...3 4 5 8 00 End of the 1st time zone 72 0 00 23 4 5 14 00 73 0 00 23 4 5 17 30 74 0 00 23 4 5 20 00 75 0 00 23 4 5 22 30 76 ECO4 from 0 00 23 4 5 23 00 Start of the 4th time zone economic 77 ECO4 to 0...

Reviews: