OPERATION 16
gun is operated the EASYSTART valve will close and the water will
stop discharging. Each time the trigger gun is closed water will
discharge through the EASYSTART valve again. This is a built in
safety feature of this unit to avoid overheating the pump and to ease
starting. The EASYSTART valve also releases any residual pressure
in the system automatically when the engine is stopped.
Never
commence work until the daily service checks have been
carried out.
STARTING THE ENGINE
Diesel Driven Units
Read the engine operators manual before attempting to start the
engine.
Connect the inlet/suction hose to a suitable tap or completely
immerse the inlet filter in the tank or sump. Turn on the tap
Ensure the lance is securely stowed
Turn on the fuel tap, if fitted.
Move the governor lever/engine stop control to the start position.
Most small diesel engines are fitted with automatic decompression
levers, operate the lever as described in the engine operators
manual.
Grasp the starter grip and pull lightly until resistance is felt, then
return to the normal position. Still grasping the starter grip pull
briskly with a “jerking” motion. The engine should now start running
normally. If not, repeat the starting procedure. Do not wrap the
starter cord around the hand, serious personal injury could be
sustained if the engine “kicks back” or backfires.
Do not allow the engine to run for more than 5 minutes with the
trigger gun closed, the water temperature will rapidly rise and will
cause damage to the water pump seals.