General safety instructions

Please read the following safety precautions carefully before putting this device to use to avoid
any personal injuries, damage  to  the  instrument,  or  to  the  target  system.  Use  this  instrument
only for its intended purpose as specified by this manual to prevent potential hazards.

Use included power cord and power supply

The enclosed power supply has been approved for use by iSYSTEM. Please contact iSYSTEM  if
you need to consider an alternative power.

Use grounding wire

Prior to applying power  to  either  the  BlueBox  or  the  target,  connect  the  device  and  the  target
system together with the included grounding wire. This is to avoid potential damage caused by
any voltage difference between the device and the target system.

Use proper overvoltage protection

Ensure proper protection to  avoid  exposing  the  BlueBox  device  or  the  operator  to  overvoltage
surges (e.g. caused by thunderstorm, mains power).

Do not operate without cover

Do not operate the device with cover removed.

Avoid circuit and wire exposure

Do not touch exposed components or wires when the device is powered.

Do not operate with suspected damage

If you suspect damage may have occurred, the BlueBox device  must  be  inspected  by  qualified
service personnel before further operation.

Do not operate the device outside its rated supply voltage or environmental range

Consult  with  iSYSTEM  before  using  equipment  outside  of  the  parameters  provided  in  this
manual.

This symbol is used within the manual to highlight further safety notices. 

Summary of Contents for iSYSTEM RH850

Page 1: ...RH850 Aurora Active Probe User Manual V1 4 September 2023 isystem com start...

Page 2: ...otential damage caused by any voltage difference between the device and the target system Use proper overvoltage protection Ensure proper protection to avoid exposing the BlueBox device or the operato...

Page 3: ...850 Aurora Active Probe 4 Specifications 5 Operation 6 mDIO Cable 8 14 pin 2 54 mm LPD Adapter 9 RH850 Aurora 34 pin to Aurora 46 pin Converter 10 Hardware Setup and Configuration 12 Accessories 13 Us...

Page 4: ...interface operating at its maximum frequency Its small and compact hardware size allows for connecting to a target microcontroller in a confined space as far as 10 m away The Active Probe supports up...

Page 5: ...ATION Communication interface to BlueBox iSYSTEM proprietary FNet Debug signal valid input voltage range 3 3V max 3 6V Power consumption Max 1 5W dependent on operation mode Number of supported AGBT l...

Page 6: ...nput O Ground GND 17 18 nEVTO Nexus Event Output I Reserved 19 20 FLMD1 Flash Mode Reserved 21 22 RESETn Reset I O Ground GND 23 24 GND Ground Not Connected NC 25 26 CLK_P AGBT Clock_P O Not Connected...

Page 7: ...use Blinking green Establishing connection with the BlueBox Blinking blue Reprogramming SPLASH Permanently magenta Golden image loaded and ready to use D FNet connector that connects the Active Probe...

Page 8: ...controlled by the debugger For example the debugger can periodically service an external watchdog through the mDIO output or just read and record an external signal through the mDIO input It must be o...

Page 9: ...Ordering code IC57176 The following pinout is valid on the target side Signal Direction Signal Description Signal Pin Pin Signal Signal Description Signal Direction O LPD LPDCLK 1 2 GND Ground O JTAG...

Page 10: ...RESET Debug Signal Reserved 9 10 NC Not Connected Ground GND 11 12 nTRST JTAG O Reserved 13 14 FLMD0 Flash Mode O Reserved 15 16 nEVTI Nexus Event Input O Ground GND 17 18 nEVTO Nexus Event Output I R...

Page 11: ...GND 11 12 nTRST Debug Signal O Reserved 13 14 FLMD0 Flash Mode O Reserved 15 16 nEVTI Nexus Event Input O Ground GND 17 18 nEVTO Nexus Event Output I Reserved 19 20 FLMD1 Flash Mode Reserved 21 22 nRE...

Page 12: ...V even before any of the devices are powered up This voltage difference is discharged over the BlueBox and the Target leading to the possible destruction of electronic components 4 Connect FNet cable...

Page 13: ...Probe IC57150 MPC5x SPC5x Aurora Active Probe IC57166 Infineon SGBT HSTCU Active Probe RH850 Aurora Active Probe Accessories Ordering Code Description BB FNET 100 1 0m FNet Cable BB FNET 300 3 0m FNet...

Page 14: ...User Notes This page is intentionally left blank...

Page 15: ...This page is intentionally left blank...

Page 16: ...www isystem com Visit our website for Support isystem com support Tutorials isystem com start Knowledge Base kb isystem com...

Reviews: