26
Clean the recovery tank / solution tank
Clean solution tank filter
Cleaning the tool
Foot pedal
Tool ejector
Removing and cleaning the squeegee
Cleaning the machine
Storage / parking of machine (machine is idle)
Store the machine with the tank cap slightly open, by:
• lifting the tank lid and turning the dosing aid upside down.
• then rest the tank lid on the dosing aid.
Service, maintenance and care
The correct maintenance of the machine is a precondition for error-free
operation and a long service life.
• Switch the machine off.
• Open the lid until the self support locates on the tank wall.
• Remove the coarse dirt sieve (yellow), empty and clean it.
• Clean the recovery tank thoroughly with water.
• Then thoroughly rinse out the solution tank with clean water.
• Check that the float is functioning correctly and that the suction filter (yellow)
is clean.
In case of damage or soiling of the float and suction filter, please refer to
page 27.
• After draining, screw the blue cap on again, close the cap at the pimched
neck and hang the hoses back in their holders again.
Caution:
Clogged filters reduce the flow of the cleaning solution. As a
consequence you may damage the floor coating.
• Switch the machine off.
• Once the solution tank has been drained, screw
the yellow cap from the solution tank filter and
pull it away from its holder.
• Rinse the filter under running water.
If necessary, the filter should be descaled with a 10% TASKI calcacid
solution.
The filter is lower than the tank outflow. A residual amount of
solution will flow out once the filter cap has been unscrewed.
• Refit the solution filter.
• Switch the machine off using the keyswitch and remove the key.
• To raise the tool, press down the foot pedal and
lock it in place.
• Press the tool ejector with your foot.
• Clean the tool under running water.
• Switch the machine off.
• Pull the two suction hoses from the squeegee support.
• Press the locking springs together. The
squeegee will thereby be released and can be
removed.
• Clean the squeegee with water using a brush.
Optimal result can only be obtained with clean and intact blades!
Caution:
Never clean the machine with high water pressure or a water
hose.
The ingress of water into the machine might cause considerable
damage to mechanical or electrical parts.
• Wipe down the machine with a damp cloth.
The dosing aid holds the tank lid slightly open,
allowing the tank to dry out. As a result, the
formation of mould and unpleasant smells can
be reduced.
Caution:
Never store the machine for longer periods with the battery
discharged. The battery could thereby be damaged and may no
longer be functional.
Caution:
Only TASKI branded spare parts must be used, otherwise
warranties and liabilities will be omitted!
Symbols:
◊
= After use,
◊◊
= every week,
◊◊◊
= every month,
⊗
= Service light
Activity
◊ ◊◊ ◊◊◊ ⊗
page
Recharge batteries
22
Clean all parts marked yellow
Drain and clean the tanks
25
Clean the machine with a damp cloth
26
For wet batteries: Top up with distilled water after
charging.
Pay attention to the control book and the
instructions of the battery manufacturer!
Clean the tank lid seal, check for cracks and
replace if necessary
Maintenance programs by TASKI service made by
TASKI technician