background image

Step 4

OPERATING INSTRUCTIONS

Insert the spray lance into the gun by pushing firmly and simultaneously 
twisting 1/4 of a turn until locked into place.

10

Fig. 4

Step 5

Connect the garden hose to water supply and turn water on.

Step 6

Plug GFCI into power receptacle.  Firmly press and release the TEST 
button, then press and release the RESET button.  The light on the 
GFCI should be illuminated. 

Fig. 5

Fig. 6

Fig. 7

Summary of Contents for TF1600

Page 1: ...ternational patents Copyright All Rights Reserved READ AND SAVE THESE INSTRUCTIONS EQUIPO ELÉCTRICO DE LAVADO CON AGUA A PRESIÓN DE 2000 PSI LEA Y GUARDE ESTAS INSTRUCCIONES Consultas problemas piezas faltantes Antes de devolver la unidad a la tienda contáctese con nuestro Departamento de Servicio al Cliente llamando al 1 866 788 5598 Este producto está protegido por patentes de los EE UU y otras ...

Page 2: ... Power Supply and Electrical Info Package Contents Assembly Instructions Operation Instructions Cleaning Techniques End of Use Storage Instructions Care and Maintenance Troubleshooting Warranty 3 5 6 7 8 9 14 15 16 17 18 Max pressure Water flow rate Electrical requirement Electrical cord High pressure hose Minimum amp source Pressure of inlet water Inlet water Soap consumption rate 2000 PSI 1 6 GP...

Page 3: ...nt 1 Read all the instructions before using the product 2 To reduce the risk of injury do not operate near children or animals 3 Know how to stop the product and bleed pressures quickly Be thoroughly familiar with the controls 4 Stay alert watch what you are doing 5 Do not operate the product when fatigued or under the influence of alcohol or drugs 6 Keep operating area clear of all persons 7 Do n...

Page 4: ...ching of the high pressure hose 22 Never tie knots or kink the high pressure hose as damage could result 23 Do not operate or store this product in temperatures below 40 F Freeze damage is not covered by the warranty 24 Carefully observe all chemical instructions and warnings before using Use only approved pressure washer cleaners Do not use bleach chlorine or any cleaners containing acids 25 The ...

Page 5: ...ically reset itself and resume normal operation after a short period of time GROUND FAULT CIRCUIT INTERRUPTER PROTECTION This pressure washer is provided with a Ground Fault Circuit Interrupter GFCI built into the plug of the power supply cord This device provides additional protection from the risk of electric shock Should replacement of the plug or cord become necessary use only identical replac...

Page 6: ... an electrical outlet Reset by simply pushing the reset button on the GFCI power plug Extension cords are not recommended unless they are plugged into a receptacle protected by a ground fault circuit interrupter Any extension cord used must be 12 AWG outdoor with maximum length of 25 feet to prevent excessive voltage loss Use only extension cords intended for outdoor use These extension cords are ...

Page 7: ...rden hose connector Spray gun Cord storage hook 35 ft power cord with GFCI Turbo spray nozzle Storage compartment Gun Lance holders Dual detergent tanks Variable spray lance 1 1 1 1 1 1 1 1 1 1 1 1 1 1 PACKAGE CONTENTS 7 Part Description Quantity A B C D E F G H I J K L A B C A D F E G H I J K L M N M N ...

Page 8: ...ASSEMBLY INSTRUCTIONS 1 Slide the storage hook onto the back of the machine as shown in Fig 1 8 Fig 1 ...

Page 9: ...d connector fitting with the o ring into the high pressure outlet and tighten the threaded nut by hand Step 3 Connect the garden hose to the machine inlet using the garden hose connector provided Before connecting run water through the garden hose not supplied to flush out any foreign matter If your water source is a well the garden hose length can only be 30 ft maximum Fig 5 Fig 2 Fig 3 Fig 4 ...

Page 10: ... twisting 1 4 of a turn until locked into place 10 Fig 4 Step 5 Connect the garden hose to water supply and turn water on Step 6 Plug GFCI into power receptacle Firmly press and release the TEST button then press and release the RESET button The light on the GFCI should be illuminated Fig 5 Fig 6 Fig 7 ...

Page 11: ...rigger to bleed any trapped air out of the unit Release trigger when water flow is steady 11 Fig 4 Step 8 Depress the ON button Note that the motor will momentarily start and then stop Step 9 Squeeze the trigger to start motor and begin pressure washing Fig 8 Fig 10 Fig 9 ...

Page 12: ...safe direction when starting the pressure washer Do not point at face or feet as serious injury could result OPERATING INSTRUCTIONS 12 The high pressure nozzle position is intended for cleaning When high pressure is required grasp the variable spray nozzle head and slide back fully toward the gun Fig 11 High Pressure Low Pressure Spray The low pressure nozzle position is intended for dispensing de...

Page 13: ...ing increases as you move the wand closer to the surface To adjust the spray pattern turn the nozzle head clockwise or counterclockwise as desired Fig 13 WARNING Do not attempt to move the turbo nozzle to adjust pressure The turbo nozzle is not adjustable Turbo Spray Nozzle To use the turbo spray nozzle first separate the variable spray nozzle from the lance Then thread the turbo nozzle into the l...

Page 14: ...rinse a small section at a time Avoid working on hot surfaces or in direct sunlight When cleaning with the pressure washer some cleaning tasks can be solved with water alone but for most tasks it is advantageous to use a detergent A detergent ensures a quick soaking of the dirt allowing the high pressure water to penetrate and remove the dirt more effectively The low pressure position provides a g...

Page 15: ...g 17 8 Store the machine and accessories in a dry climate controlled environment Do not store the machine or accessories in a place where the temperature could drop below 40 F FREEZE DAMAGE IS NOT COVERED BY THE WARRANTY Fig 17 2 Allow detergent to remain on the surface for short time before rinsing Do not allow the detergent to dry on the surface 3 Rinse with clean water under high pressure On a ...

Page 16: ...forcing stiff wire through center hole 2 Backflush the nozzle with water Restart the pressure washer and depress the trigger on the spray gun If the pressure is still too high repeat above items 1 2 Lubrication The pressure washer is designed with a permanent lubrication system Conventional oil check and oil changes are not necessary NOTE In case of oil leakage contact our customer service departm...

Page 17: ...size too small Use proper extension cord as recommended on Operator s Manual page 6 Nozzle partially blocked Clean nozzle as instructed on page 16 Excessive pressure Clean nozzle as instructed on page 16 Water or oil leaking from bottom of pump A small amount of leakage is normal If excessive leaking occurs call Customer Service Trigger will not move Spray gun safety lock engaged Release safety lo...

Page 18: ... caused by abuse accident improper repair or failure to perform normal maintenance Use of improper chemicals or noncompliance with the operators manuals instructions Sales outside of the United States or Canada Any other expense including con sequential damages incidental damages or incidental expenses including damage to property Some states do not allow the exclusion or limitation of incidental ...

Reviews: