©Copyright Task Force Tips, Inc. 2008-2014
LIY-500 May 12, 2014 Rev10
38
4.13 ELECTRICAL
RC MONITOR
AERIAL TRUCK
INSTALLATION
Two versions of the RC monitor have been designed for installation on aerial device trucks, the “-L” and “-P” versions. The “-L”
version is supplied with one cable for connecting discrete inputs into the electronics enclosure, typically connections to a Canbus
output module or toggle switches located at the turntable. The “-P” version is supplied with two cables for connecting discrete inputs,
one cable typically for controls located in the basket and one cable for controls located at the turntable.
4.13.1 ELECTRONICS ENCLOSURE MOUNTING
Select proper enclosure location. Enclosure is
designed to be surface mounted and the size is 5 3/4”
x 10” (146mm x 254mm). Height of enclosure is 2
1/4” (57mm). Refer to Figure 4.13.1 for mounting hole
dimensions.
9 7
16
"
[239mm]
3 9
16
"
[90mm]
Fig 4.13.1
Electrical Enclosure Mounting Hole Dimensions
4.13.2 ELECTRICAL WIRING
On aerial devices, the installer will supply the required cables that run up the ladder or boom. Be sure to perform voltage drop
calculations to verify that the supply voltage will remain at an acceptable level during monitor operation.