4.6 HORIZONTAL ROTATION TRAVEL STOPS
The range of horizontal rotation travel for the manual Monsoon monitor is continuous 360 degrees. The motorized version is limited to
450 degrees total horizontal rotation travel, or 225 degrees from either side of a straight ahead position. Horizontal rotation travel stop
bolts may be installed in the monitor to limit travel. Note that left and right are relative to the “Straight Ahead Reference Mark” (the
Straight Ahead Reference Mark and refer to the nozzle’s discharge direction as seen from an operator’s position behind the nozzle. The
following figures show the range of travel for the various stop bolt locations and give installation notes.
Figure 4.6A
Horizontal Rotation Travel Limits
Figure 4.6B
Horizontal Rotation Travel Stops
LOCATION OF
STRAIGHT AHEAD
REFERENCE MARK
RC MODELS
WITH NO STOP BOLTS
INSTALLED HAVE A HORIZONTAL
ROTATIONAL TRAVEL LIMIT OF
225° LEFT AND RIGHT OF THE
STRAIGHT AHEAD REFERENCE MARK
MANUAL MODELS
WITH NO STOP BOLTS
INSTALLED HAVE A CONTINUOUS
360° HORIZONTAL ROTATIONAL TRAVEL
225°
LEFT
225°
RIGHT
135°
RIGHT
135°
LEFT
90°
LEFT
90°
RIGHT
45°
RIGHT
45°
LEFT
STRAIGHT AHEAD
REFERENCE MARK
90° RIGHT
45° RIGHT
SET
SCREW
90° LEFT
135° LEFT & RIGHT
45° LEFT
8° LESS RIGHT TRAVEL WITH
EVERY ADJUSTMENT DISC
INSTALLED ON THIS SIDE OF
THE STOP BOLT
8° LESS LEFT TRAVEL WITH
EVERY ADJUSTMENT DISC
INSTALLED ON THIS SIDE OF
THE STOP BOLT
To change the Horizontal Rotational Travel Limits:
1. Remove the Set Screw
2. Insert 1 Adjustment Disc (Not included. Contact tft.com for parts)
in the bolt hole for every 8° of travel limitation
3. Replace the Set Screw with the Stop Bolt