DM-3200 Release Notes
0
TASCAM DM-3200 Release Notes V1.50
TIME EVENT section
You can set up to 16 time events in the
GPI EVENT LIST
.
How to control the GPI EVENT LIST
To move the cursor vertically within the list, use either
the up and down cursor key or the
POD 4
knob.
To move the cursor horizontally (across the columns),
use either the right and left cursor key.
Arrows at the top and the bottom of the right-hand side
of the list mean that there are more time events outside
of the screen. To scroll the list vertically, use the
POD
4
knob. You cannot use the up and down cursor key to
scroll the list.
Selecting the port
GPI
ports can be selected in the
PORT
column on the
GPI
EVENT LIST
. You can only select a port whose item has been
set to be a
TIME EVENT
in the
GPI CONFIG
section. Use either
the cursor key or the
POD 4
knob to highlight a cell in the
PORT
column that you want to edit, use the
JOG/DATA
dial
to select the port, then press the
ENTER
key to confirm the
selection. You can select the same port for more than one
time event.
Setting the time
You can set the time when an event is to be executed. Use
either the
cursor
key or the
POD 4
knob to highlight a cell
in the
TIME
column that you wish to set, use the
JOG/DATA
dial to set the time, then press the
ENTER
key to confirm.
Setting the type
You can set the output waveform type for each of the
GPI
ports.
Use either the cursor key or the
POD 4
knob to highlight a
cell in the
TYPE
column that you want to edit, then use the
JOG/DATA
dial to select the type.
: output low pulse at the designated time
: output high pulse at the designated time
: change to low level at the designated time
: change to high level at the designated time
ON/OFF setting
Set this to
ON
when you want to activate the settings of
individual
GPI
ports.
ª
•
•
•
Editing the GPI EVENT LIST
You can edit the
GPI EVENT LIST
by highlighting the button
at the bottom right on the screen and then by pressing the
ENTER
key.
SORT PORT
: This sorts the
GPI EVENT LIST
by port numbers.
SORT TIME
: This sorts the
GPI EVENT LIST
by time.
CAPTURE TC
: This sets the
TIME
of the highlighted time
event to the current timecode value.
DELETE
: This deletes the highlighted time event.
NOTE
You can scroll within the GPI EVENT LIST while the
cursor is pointing at CAPTURE TC or DELETE using the
JOG/DATA dial. The JOG/DATA dial icon at the upper
right corner of the list will become black.
ª