![Tascam Dante AE-4D Owner'S Manual Download Page 8](http://html1.mh-extra.com/html/tascam/dante-ae-4d/dante-ae-4d_owners-manual_3658648008.webp)
8
TASCAM AE-4D
Names of parts
Front panel
1
STATUS indicator
The
STATUS
indicator blinks blue under the following
conditions.
o
When no LAN cable is connected
o
When the Dante module is not operating properly
2
SAMPLE RATE indicator
The lit/unlit state of the three SAMPLE RATE indicators
(44.1k, 48k and ×2) show the sampling frequency status
of the unit.
44.1 kHz
48 kHz
x2
44.1 kHz
Lit
Unlit
Unlit
48 kHz
Unlit
Lit
Unlit
88.2 kHz
Lit
Unlit
Lit
96 kHz
Unlit
Lit
Lit
3
IN SIG indicators
These light when sound is being input through the dig-
ital inputs.
Input is judged to have occurred when the signal level
exceeds −60 dBFS.
4
OUT SIG indicators
These light when sound is being output through the dig-
ital outputs.
Output is judged to have occurred when the signal level
exceeds −60 dBFS.
Rear panel
5
AES/EBU IN connectors
These are balanced XLR AES3-2003/IEC60958-4 (AES/
EBU) format digital audio input connectors.
NOTE
When the sampling frequency is 88.2 or 96 kHz, use the
AES/EBU IN 1-2
connector. The
AES/EBU IN 3-4
connec-
tor cannot be used.
6
AES/EBU OUT connectors
These are balanced XLR AES3-2003/IEC60958-4 (AES/
EBU) format digital audio output connectors.
NOTE
When the sampling frequency is 88.2 or 96 kHz, use the
AES/EBU OUT 1-2
connector. The
AES/EBU OUT 3-4
connector cannot be used.
7
DC IN/DC OUT connectors
The DC-IN connector is above, and the
DC-OUT
connec-
tor is below. (Left is 12V, and right is GND.)
These connectors are specifically for power daisy-chain-
ing.
ATTENTION
Disconnect the AC adapter before connecting the
DC IN
and
DC OUT
connectors.
NOTE
i
Power daisy-chaining can be enabled by connecting the
DC OUT
and
DC IN
connectors. Power daisy-chaining of
up to two units is possible
i
When powering by PoE, the first unit in the powerdai-
sy-chain will not be powered. In this case, use a dedicat-
ed PS-P1220E AC adapter (sold separately) to power the
first unit in the daisy chain.
8
DATA/DATA+PoE connectors
These are Dante transmission connectors.
Use to connect the unit to a Dante network.
Use the DATA+PoE connector when connecting to a
switching hub that supports PoE power supply. In this
case, use of an AC adapter is not necessary.
Either connector can be used when using a switching
hub that does not support PoE power supply.
9
RESET button
This resets the settings.
Press and hold for 5 seconds to reset all Dante settings.
Press and hold for 10 seconds to reset all unit settings.
Summary of Contents for Dante AE-4D
Page 14: ...14 TASCAM AE 4D...
Page 26: ...26 TASCAM AE 4D...
Page 38: ...38 TASCAM AE 4D...
Page 60: ...60 TASCAM AE 4D...
Page 61: ...TASCAM AE 4D 61 V P AC AC N AC AC 1 AC AC AC AC AC 100 100 DC 20cm 1U 10cm...
Page 62: ...62 TASCAM AE 4D V C Y V P AC AC AC N AC AC AC AC AC...
Page 63: ...TASCAM AE 4D 63 V O AC V 5 1...
Page 67: ...TASCAM AE 4D 67 q w DC IN 12V AC PS P1220E e AC PS P1220E 1 4 2 3 4 4 7 1mm 1 2 2 3 4 4...
Page 72: ...72 TASCAM AE 4D...
Page 77: ......
Page 78: ......