18
TASCAM 302MKII
The following messages are displayed on the tape counter when two or more 302MkII units are in use, one serving
as the master machine and the others as the slave machines, and an error is detected :
Problem
Possible Cause
Solution
Continuous record/play
impossible
REV MODE switch set to
Ä
or
ä
.
Set switch to CONT.
OFF/SLV/MSTR switch set to SLV or
MSTR.
Set switch to the left OFF position.
Poor sound quality
Heads are dirty.
Clean them, as stated above.
Inappropriate DOLBY NR switch
setting.
Set switch to the setting used for
original recording.
Heads are magnetized.
Demagnetize them, as stated above.
Recording impossible
Erase-protection tabs broken off the
cassette.
Cover tab holes with plastic tape.
Error Messages
Display
Problem
Solution
Err2
Commands interrupted somewhere
because of incoherent switch settings
Make settings coherent throughout the
system.
Err3
Incorrect EXT CONTROL connection
Correct connection.
Troubleshooting