background image

Warranty 

We warrant that commencing from the date of shipment to you (and in case of 
resale to you by a Tarana partner, commencing not more than 90 days after our 
original shipment), and continuing for a period of twelve (12) months, the hardware 

will be free from defects in material and workmanship under normal use. This 
limited warranty is not transferrable. Your sole and exclusive remedy and our entire 

liability under this limited warranty will be, at our option, shipment of a 
replacement or a refund of the purchase price, if you notify us of the defect within 
the warranty period and return the hardware to us freight and insurance prepaid. 

Parts used in replacement may be new or reconditioned. Our obligations are 
conditioned upon the return of affected hardware in accordance with our then-

current standard Return Material Authorization (RMA) procedures. This limited 
warranty does not cover (a) damage resulting from (i) use in other than the wireless 
transport applications defined in our product documentation; (ii) use not in accord 

with applicable spectrum regulations; (iii) handling, testing, installation, operation, 
maintenance, service, repair, alteration, modification, or adjustment outside of 
practices and conditions defined in our product documentation; (iv) other general 

misuse, accident, liquid intrusion, or neglect; (v) unauthorized radio connection to 
equipment not supplied by us; (vi) illegal or unauthorized alteration of software or 

firmware; (vii) acts of nature (such as lightning) or performance failure of other 
equipment (including electrical transients and over/under voltage); (b) scratches, 
discoloration, or other cosmetic damage to surfaces that do not affect operation; (c) 

normal and customary wear and tear; and (d) any product where serial number, 
revision level, part number, date code, warranty data, tamper-proof seals, or quality 
assurance decals have been removed or altered. 
DISCLAIMER:  Except as specified above, all express or implied conditions, 
representations, and warranties including, without limitation, any implied 
warranty or condition of merchantability, fitness for a particular purpose, non-
infringement, satisfactory quality, non-interference, accuracy of informational 
content, or arising from a course of dealing, law, usage, or trade practice, are 
hereby excluded to the extent allowed by applicable law and are expressly 
disclaimed by us.

 To the extent an implied warranty cannot be excluded, such 

warranty is limited in duration to the express warranty period. This disclaimer and 
exclusion will apply even if the express warranty set forth above fails of its essential 
purpose. 

 

Tarana products are not designed, intended, or certified for use in 
communication systems for, or relating to (a) weapons or weapons systems, 
(b) nuclear facilities, (c) air traffic control or other mass transportation systems, 
(d) life support systems or other medical devices, (e) applications where 
electrical sparks could trigger explosions or fires, or (f) any other systems, 
devices or applications in which the failure of the product to operate as 
intended may lead to death, bodily injury, or catastrophic property damage 
(each an “Unauthorized Use”).  Many of such Unauthorized Uses would require 
specific industry certification which has not been sought or obtained for the 
Tarana products. 
LIABILITY.

  We will not be liable for any special, incidental, indirect, or 

consequential damages (including lost profits or property damage) arising out 
of or relating to the sale of the goods to you or your possession, installation, 
use, operation or repair of the goods, even if the goods are nonconforming, 
defective, infringing, delayed, or not delivered, and even if we have been 
advised of the possibility of such damages.  You agree to indemnify and hold 
us harmless from any claims, suits, demands and causes of action arising out 
of or relating to your possession, installation, use, operation or repair of the 
goods.  Notwithstanding any other provisions of this document, in no event 
will our total liability in connection with or relating to the goods exceed the 
amount you have paid us for the goods.

 

Summary of Contents for G1 RN

Page 1: ...TaranaG1RNManual ...

Page 2: ...a Statements 7 Deployment in the European Union CE Mark 8 Preparation 10 Tools Required 10 Tarana Hardware and Peripherals 10 Customer Supplied Equipment 10 Physical Installation 11 Preparing the RN 11 Wall or Surface Mounting the Elevation Bracket 12 Pole Mounting the Elevation Bracket 12 Installing the RN 13 Powering Up the RN 14 Warranty 15 NOTE For the most up to date instructions please downl...

Page 3: ...port when no fiber is connected therefore avoid exposure to laser radiation and do not stare into open apertures FCCInformation The FCC occupational controlled limit for maximum permissible exposure MPE is 5 mW cm2 It is estimated that the maximum power density at the radome is 1 25 mW cm2 which is below the FCC MPE limit Since the power density for an occupational controlled environment is less t...

Page 4: ... to this equipment that are not in accordance with the provisions of this User Guide the Installation Guide or other supplementary documentation may result in personal injury or damage to the equipment and may void the equipment warranty AVERTISSEMENT Tout réglage ou modification faits à cet équipement hors du cadre édicté par ce guide d utilisation ou par toute autre documentation supplémentaire ...

Page 5: ... to bend them beyond their minimum bending radius Protect cover unconnected optical fiber connectors with dust caps Grounding Connections Reliable grounding of the G1 chassis must be maintained Mains Power Supply Routing G1 DC power is not to be routed with any AC mains power lines They are also to be kept away from any power lines which cross them Maximum Ambient Temperature The maximum ambient t...

Page 6: ... 2013 08 IP X7 EN 62368 1 2014 2nd Edition IEC EN 60950 22 Immunity EN61000 4 5 Level 4 AC Surge Immunity EN61000 4 4 Level 4 Electrical Fast Transient Burst Immunity EN61000 4 3 Level 4 EMC Field Immunity EN61000 4 2 Level 2 ESD Immunity Radio Approvals FCC Part 15 Subpart E 15 407 RSS 192 RSS 197 RSS 199 EN 302 326 2 EN 302 502 EMI and susceptibility FCC part 15 207 15 209 ICES 003 RSS Gen CAN I...

Page 7: ...ergy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correc...

Page 8: ...ce including interference that may cause undesired operation of the device Le produit final doit être installé par un professionnel Cet appareil numérique de la classe B est conforme à la norme NMB 003 du Canada IC avertissements d exposition RF Pour satisfaire les exigencies d IC en ce qui a trait aux expositions aux RF pour RF dispositifs de transmission les distances suivantes doit être mainten...

Page 9: ...s Tarana Wireless systems are designed to be operated as to avoid contact with the antennas by the end user It is recommended to install the system in a location where the antennas can remain at least a minimum distance as specified from the user in accordance to the regulatory guidelines which are designed to reduce the overall exposure of the user or operator To meet radiation exposure requireme...

Page 10: ... Ova oprema je u skladu s osnovnim zahtjevima i drugim relevantnim odredbama Direktive 2014 53 EU English This equipment is in compliance with essential requirements and other relevant provisions of Directive 2014 53 EU Български Bulgarian Това оборудване е в съответствие с основните изисквания и съответващите разпоредби на Директива 2014 53 EU Cesky Czech Toto zařízení je v souladu se základními ...

Page 11: ...are and Peripherals RN radio unit RN mounting kit o 1pcs RN chassis bracket o 1pcs RN elevation Bracket o 8pcs M5 flanged head screw with thread lock o 2pcs Wormdrive clamps Single hole ground lug Passive PoE injector with power cord 1 m Ethernet cable Customer Supplied Equipment Ethernet cable shielded CAT5e CAT6 RJ45 connectors Grounding wire 14 AWG Earthing hardware Lightning and surge protecti...

Page 12: ...hat will not damage the plastic radome Step 2 Place the chassis bracket onto the back of the RN and locate it onto the 4 threaded holes Step 3 Using an 8mm hex socket install the four screws and gradually torque them in a crossing pattern to the specified torque value of 6 N m 4 5 ft lb Step 4 Partially install one screw on each of the elevation attachment tabs of the chassis bracket in the locati...

Page 13: ... in diameter can be used with the bracket without issue Do not attempt to use fasteners smaller than 6mm and never modify the elevation bracket by drilling for larger than 8mm fasteners as it will damage the corrosion protection of the finish Step 3 Install the elevation bracket with its elevation tabs facing outward and oriented as shown PoleMountingtheElevationBracket Step 1 Route the opened scr...

Page 14: ...nd around the terminated RJ45 connector and cable Step 5 Carefully plug the RJ45 connector into the RN making sure there is an audible click made by the connector properly seating into RJ45 receptacle on the main PCB inside the RN enclosure If the click is not heard a slight pull on the Ethernet cable is sufficient to check if the cable has been properly seated or not DO NOT FORCIBLY pull on the E...

Page 15: ...rana POE injector apply power to Ethernet cable Step 2 Verify LED operation Step 3 Once the RF link is established optimize alignment using RN local WebUI Step 4 Torque the four screws used on the elevation attachment tabs to 6 N m 4 5 ft lb Step 5 Run final checks a Authentication b Internet connectivity c Internet speed test ...

Page 16: ...r implied conditions representations and warranties including without limitation any implied warranty or condition of merchantability fitness for a particular purpose non infringement satisfactory quality non interference accuracy of informational content or arising from a course of dealing law usage or trade practice are hereby excluded to the extent allowed by applicable law and are expressly di...

Reviews: