background image

            

Working 

amplifier

Battery with voltage 

below 9V

above 17V

Battery with voltage

Temperature above operating 

limit (> 85 ° C)

4 - NEGATIVE POWER SUPPLY: 

Use a cable of minimum 4 AWG up to maximum of 1/0 AWG as short as possible, 

connected to the negative battery pole.

2 -  POSITIVE  POWER  SUPPLY: 

Use a minimum 4  AWG up to maximum of 1/0  AWG cable direct from the 

positive battery terminal, with fuse or circuit breaker (200A), as close to it as possible.

1 - SMART COOLER:

 This amplifier has two internal ventilation fans. For perfect functioning, the amplifier must 

be installed in a cool and aired place with at least 1” (25mm) space around the heatsink for proper heat spreading. 
The usually working temperature of amplifier is 65°C.

3 - TERMINAL REMOTE: 

It must be connected to the remote output of the head unit using a 18 AWG cable.

We recommend that all cables have tinned ends for better electrical contact.

In case of power bus bar using, avoid tightening with extenders on the allen wrench, as excessive torque may 
break the the terminal.

11

Power supply connector 

LEDS indicators & protection system

Effect bars
with the last
schedule

Effect bars
blink 2x
in red

Effect bars
flash 3x
in red

Effect bars
flashing red
6x per second
continuously
Effect bars
flashing yellow
1sec. lit
1 sec. wiped out

Blue LED on

Red LED
flashes 2x

Red LED
flashes 3x

Red LED
flashing 6x per
second continuously

Yellow LED
flashing 1 sec. on
1 sec. off

ENGLISH

POWER 

INPUT

1

1

2

3

4

The fan and ventilation openings are responsible for cooling the amplifier when it is in 
use, so it cannot be obstructed.

CAUTION

Before making any connections to the power terminals, make sure that the negative (-) 
of the vehicle battery is disconnected.

CAUTION

Conditions

 LED of Monitor

RGB LEDs 

Short circuit on output or 

between output terminal to GND

The thermal protection waits for cooling before restarting.
If it goes into protection, the amplifier will automatically restart.

Example:

Low Battery Protection:

 Working amplifier       Red LED (LED Monitor) or Smart LEDS, flashes 2x        Red LED 

(LED monitor) or Effect bars, flashes 2x         Amplifier restarts.

Summary of Contents for THE BIG BOSS 3 BASS

Page 1: ...A instala o deste produto dever ser feita por um profissional qualificado The installation of this product must be made by a qualified professional...

Page 2: ...oaparelhodesuafabrica o Estagarantiaexclui Produtosdanificadosporinstala oincorreta infiltra ode gua viola oporpessoasn oautorizadas A TARAMPS localizada Rua Ab lio Daguano 274 Res Manoel Martins Alfr...

Page 3: ...ar emsuperaquecimento fuma a danosaoproduto ferimentosouqueimaduras Antes de fazer qualquer conex o ao amplificador desconecte o terminal negativo da bateria Nunca instale o amplificador em locais exp...

Page 4: ...REQ 5 BASSBOOST FILTRO LOW PASS LPF Ajuste vari vel de 60Hz a 200Hz que determina o fim da frequ ncia de opera odoamplificador 7 SPEAKER Sa da positivo e negativo para a conex o dos transdutores alto...

Page 5: ...ereiniciado Aprote ot rmicaaguardaoresfriamentoparaent oreiniciar Exemplo Prote o de bateria baixa Amplificador funcionando LED Vermelho Monitor de LED pisca 2x LED Vermelho monitordeLED ouBarrasdeefe...

Page 6: ...1 Flag 2 Flag 3 Flag 4 Configur vel Configur vel Configur vel Configur vel Configur vel Configur vel Configur vel Configur vel PORTUGU S BR Efeitos de cores 05 Clickr pido Alternaotipodeefeito Altera...

Page 7: ...entarasbitolasdoscabos Bitola do cabo remote _________________________________________________0 75mm Bitola de fia o e fus vel recomendados CUIDADO Qualquer liga o nos conectores de alimenta o entrada...

Page 8: ...a 2 30A 238 x 71 x 240mm 8Hz 200Hz 3dB 60Hz 200Hz 12dB 8 Vari vel 3 00Kg 35Hz 60Hz 90dB 4V 0 2V 0 10dB Curto circuito na sa da prote o de tens o baixa alta e 17VDC 8Hz 30Hz 12dB 8 Vari vel 190A 3000W...

Page 9: ...assistance 07 Term of warranty TheBigBoss line presentation Smartlinepresentation 08 Introduction Keyrecommendations LEDsindicators protectionsystem 11 Installation Recommendedwiregauge fuse 09 Funct...

Page 10: ...don tthrowitondomesticwaste Itmustbecollectedby anusedelectronicproductdisposalserviceforproperrecycling To ensure proper use please read through this manual before using the amplifier It is speciall...

Page 11: ...tputsignal levelsofvariousheadunitsmodelsonthemarket Itispossibletoadjustfrom4V minimumsensitivity to 0 2V maximumsensitivity 2 OUT Audiosignaloutput Sendsthesameinput IN signaltoanotheramplifier allo...

Page 12: ...the allen wrench as excessive torque may breakthetheterminal 11 Power supply connector LEDS indicators protection system Effect bars with the last schedule Effect bars blink 2x in red Effect bars flas...

Page 13: ...13 Flag 1 Flag 2 Flag 3 Flag 4 Configurable Configurable Configurable Configurable Configurable Configurable Configurable Configurable Color e ects 12 Longclick Togglesthecolorpaletteoftheselectedeffe...

Page 14: ...___________________9 AWG Positive negativepowersupplycable_____________________Min 4 AWG Max 1 0 AWG Installation Recommended wire gauge fuse CAUTION All connections to power supply input and output c...

Page 15: ...RMS 278A 90dB 0 10dB 190A 35Hz 60Hz Output short circuit low high supply voltage and 6 60lb 75 8Hz 30Hz 12dB 8 Variable Thermal protection 1700W RMS 60Hz 200Hz 12dB 8 Variable 17VDC 8Hz 200Hz 3dB 10K...

Page 16: ...MN_019706_R00 Fabricado por Manufactured by TARAMPS ELECTRONICS LTDA CNPJ TAX ID 11 273 485 0001 03 R Jo o Silv rio 121 Res Manoel Martins Alfredo Marcondes SP Ind stria Brasileira Made in Brazil...

Reviews: